Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
To take more accurate measurements in noisy locations this True RMS is the perfect solution. With its slender jaws, this Clamp-On Multimeter has the ability to take measurements in even the most constricted locations. It is a very resourceful tool to have on hand for the fact that it is also capable to measure capacitance and frequency. When measuring frequency it can be done with either the multimeters jaw or test leads.
Features:
TRMS Measurement
AC & DC voltage to 600V
AC current to 600A
Thin jaws to get in tighter spots
Continuity buzzer
Capacitance to 3000 uF
Frequency measurement
In rush current
Can handle conductors up to 26mm (1.02) in diameter
Hold & Maximum reading functions
Auto ranging
Auto power off
Overload protected
Rubber over-molded case
Spec Summary:
Display:
3-3/4 digits 4000 counts LCD display
Update Rate:
3 per second nominal
Polarity:
Automatic
Operating Temperature:
0°C to 40°C; < 80% RH for temperature up to 31°C decreasing linearly to 50% RH at 40°C
Altitude:
Operating below 2000m; Indoor use
Storage Temperature:
-20°C to 60°C, < 80% RH (with battery removed)
Temperature Coefficient:
Nominal 0.15 x (specified accuracy)/°C @ (0 °C ~ 18 °C or 28 °C ~ 40 °C)
Low Battery:
Below approx. 2.4V
Power Supply:
3V coin battery IEC-CR2032
Power Consumption:
2.8 mA typical except that 3.3 mA typical for ACA function
Electrial Spec Accuracy (23 °C ± 5 °C & < 75% R.H.):
Function
Range
Accuracy
DC Voltage
400.0 mV
±( 0.3% + 4 digits)
4.000, 40.00, 400.0V
±( 0.5% + 3 digits)
600 V
±( 1.0% + 4 digits)
NMRR:
>50 dB @ 50/60Hz
CMRR:
>120 dB @ DC, 50/60 Hz, Rs=1 kΩ
Input Impedance:
10 MΩ, 30 pF nominal (1000 MΩ for 400.0 mV range)
Transient Protection:
6.5 kV (1.2/50 μs surge)
AC Voltage (50Hz ~ 500Hz):
4.000, 40.00, 400.0V
±( 1.5% + 5 digits)
600V
±( 2.0% + 5 digits)
CMRR:
>60dB @ DC to 60 Hz, Rs=1 kΩ
Maximum Crest Factor:
< 1.75 : 1 at full scale & < 3.5 : 1 at half scale limited to
fundamental and harmonics, that fall within the meter
specified AC bandwidth for non-sinusoidal waveforms
Imput Impedance:
10 MΩ, 30 pF nominal
Transient Protection:
6.5 kV (1.2/50μs surge)
ACD-10 Plus:
True RMS sensing - 5% to 100% of range
AC Current (Clamp-on 50Hz/60Hz)
Range:
Accuracy 1) 2) 3):
40.00, 400.0, 600A
±( 1.5% + 8 digits)
Overload: Protections:
ACA Clamp-on jaws : 600 A rms continuous
ACD-10 Plus:
True RMS sensing - 10 % to 100 % of range
1) Max Induced error from adjacent current carrying conductor: 0.05 A
2) Specified accuracy is from 1% to 100% of range and for measurements made at the jaw center. When the conductor is not positioned
at the jaw center, position errors introduced are: Add 2% to specified accuracy for measurements made BEYOND jaw marking
lines (toward jaw opening)
3) Add 8 digits to specified accuracy @ reading < 10% of range
Resistance:
400.0 Ω
±( 0.8% + 8 digits)
4.000, 40.00, 400.0 kΩ
±( 0.6% + 4 digits)
4.000 MΩ
±( 1.0% + 4 digits)
40.00 MΩ
±( 2.0% + 4 digits)
Open Circuit Voltage :
0.4 VDC typical
Transient protection :
6.5 kV (1.2/50μs surge)
Frequency:
Function
Sensitivity (Sine RMS)
Range
Accuracy
400.0 mVac
350mV 1
0 Hz ~ 2 kHz
±( 0.5%+4 digits)
4.000 Vac
1V
5 Hz ~ 5 kHz
±( 0.5%+4 digits)
4.000, 40.00 Vac
32V
5 Hz ~ 100 kHz
±( 0.5%+4 digits)
400.0 Vac
90V
5 Hz ~ 10 kHz
±( 0.5%+4 digits)
600 Vac
500V
5 Hz ~ 5 kHz
±( 0.5%+4 digits)
400.0 Aac
60A
40 Hz ~ 400 Hz
±( 0.5%+4 digits)
Display Counts:
5000
Resolution:
0.001Hz
Overload Protection:
ACA Clamp-on jaws : AC 600A rms continuous
Transient Protection:
VAC input jacks : 6.5kV (1.2/50μs surge)
Capacitance:
Range 1):
Accuracy 2) 3):
500.0μF, 5.000μF, 50.00μF, 500.0μF, 3000μF
±( 3.5% + 6 digits)
1) Additional 50.00nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8V (approximately half full battery).
Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V
Transient Protection:
6.5 kV (1.2/50 μs surge)
Audible Continuity Tester:
Audible Indication:
between 10 Ω and 120 Ω.
Transient Protection:
6.5 kV (1.2/50 μs surge)
Diode Tester / Open Circuit Voltage Test Current:
(Typical):
< 1.6 VDC @ 0.25 mA
Transient Protection
6.5 kV (1.2/50 μs surge)
Max Hold* (where applicable): Specified accuracy ± 50 digits for changes > 25 ms in duration