Professional Equipment - Your testing & inspection equipment source

View Cart My Account Fax Order
Jul 20 08
HomeAbout UsFree CatalogContact UsCustomer ServiceCatalog Express Ordering
SEARCH
Can't Find What You’re Looking For? Click Here - We Can Help You
Buy by BrandsClearance
Fluke StoreFlir StoreExtech StoreMannix Store
Print
Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit
Your Price:
$5,400.00

Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit

Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit measures nitric oxide and nitrogen dioxide
Item #: G501-8239
Manufacturer: Bacharach
Manufacturer Item #: 24-8239
Product Type: Combustion Gas Analyzers
Call for availability 1-800-334-9291.
Buy Now
List Price: $5,400.00
   
Purchase this product with O2 Sensor for only $187.95 more!
Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit + Oxygen Sensor For PCA 20    Buy Both Now

Features & Applications:

Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit adds a large touch-screen display to a full feature residential,commercial, and light industrial grade analyzer, to provide the ideal tool for the service technician who needs to determine carbon monoxide (CO) safety, combustion efficiency, and emissions compliance. The touch-screen display shows up to 11 different measurements and calculations at one time in a large, easy to read font.

The Fyrizer directly measures flue gas O2, CO, NO, NO2,stack, primary and ambient temperature, pressure and draft. The analyzer also calculates and displays combustion efficiency, stack loss, excess air and dew point temperature. Additionally, the Fyrizer calculates CO, NO, NO2 to a user selected O2 reference.

The analyzer comes standard with advanced communication capabilities and data storage for 890 complete combustion records. Through its built-in IR port, test information can be sent to a printer or PC for record keeping. Customer information can be quickly entered into the analyzer's memory using a touch-screen alphanumeric keyboard.

Features:

  • Includes a heated sampling hose which is attached to the analyzer
  • Heated sampling hose removes water condensation from the sample so you can accurately measure NO and NO2 gas
  • 12" probe with 10' hose and cable
  • Probe stop
  • Ambient temperature probe
  • Additional water trap and soot filters
  • Leather case with magnetic holders
  • Battery charger
  • Hard carrying case
  • Directly measures and displays flue gas O2, CO, CO (high), stack and ambient temperature, pressure and draft
  • Calculates and displays combustion efficiency, stack loss, excess air, and dew point temperature
  • Calculates CO to a user selected O2 reference
  • Large backlit touch-screen display shows all combustion data or emissions data values simultaneously
  • Touch-screen interface for analyzer set-up and customer data entry
  • Real time graphical display of any measured or calculated test value
  • Hydrophobic filter that prevents water from entering the instrument
  • CO by-pass function that protects the CO-low sensor from high concentrations of CO
  • Stores up to 890 combustion test records for downloading to PC or printer
  • Saved test records can be recalled to the display screen at any time
  • Manual CO overload protection
  • Wireless interface to printer & PC

Spec Summary:

Measurement Ranges:

Oxygen: 0.1 to 20.9%
Carbon Monoxide: 0 to 4000 ppm (hydrogen compensated)
Carbon Monoxide (high): 4001 to 16000 ppm
Nitric Oxide: 0 to 2000 ppm
Nitrogen Dioxide: 0 to 500 ppm
Stack Temperature: 0 to 1562°F
Primary/Ambient Air Temperature: 0 to 257°F
Pressure Draft: ±15.7 inches WC

Calculation Ranges:

Combustion Efficiency: 0 to 100%
Stack Loss: 0 to 100%
Excess Air: 0 to 250%
Carbon Dioxide (dry basis): 0 to a fuel dependant max. value
NO referenced to O2: 0 to 32000 ppm
NO2 referenced to O2: 0 to 32000 ppm

Accuracy:

Oxygen: ±0.3% O2
Carbon Monoxide: ±5% of Rdg or ±20 ppm
whichever is greater (0 to 2000 ppm)
±10% of Rdg (2001 to 16000 ppm)
Nitric Oxide: ±5% of Rdg or ±5 ppm
whichever is greater
Nitrogen Dioxide: ±5% of Rdg or ±5 ppm
whichever is greater
Stack Temperature: ±4°F (0 to 257°F)
±6°F (258 to 481°F)
±8°F (482 to 751°F)
Primary/Ambient Temperature: ±2°F
Pressure/Draft: ±3% of Rdg or 0.02 inches WC

Size:

5.8"H x 7.6"W x 2"D

Weight:

3.6 lbs. with batteries and probe

Power Source:

Four AA size rechargeable NiCad batteries, min. of 4 hours
of continuous operation.

Warm-up Time:

60 seconds



Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit

Buy Now
  Purchase this product with O2 Sensor for only $187.95 more!
Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit + Oxygen Sensor For PCA 20    Buy Both Now

Enter your email address to receive our newsletter! You'll receive special offers, discounts, information on new products and more!

Submit

You are viewing...

Bacharach Fyrizer Combustion and Emissions Gas Analyzer 270 Kit
Item#: G501-8239

 


ABOUT SSL CERTIFICATES
Reference Number : P1015
Electrical  Environmental Equipment  Gas Detectors  Hand Tools  HVAC  Inspection & Business Forms  Ladders  License/ Exam-Prep  Light Meters  Locators  Measuring Tools  Moisture Meters  New Products  Pest Control  Plumbing  Safety Products  Sound Meters  Specials  Thermometers  Tool Storage  Workwear  Work Lights 
Home  Cart  Request a Catalog  Contact Us  International Sales  Customer Service  Site Map  Express Shop  About Us  Alliance 
Professional Equipment is a division of Lab Safety Supply, Inc. ©2008 Lab Safety Supply, Inc.
PO Box 5197 Janesville, WI 53547-5197 USA
Phone: 1-800-334-9291  Email: info@professionalequipment.com