Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
The Informant 2, Refrigerant Gas Detector's unique combination of
state-of-the-art patented sensor technology, advanced software design and
microprocessor controlled circuitry offers you unmatched precision coupled with tremendous speed. It is unquestionably the most sensitive, most reliable, most accurate leak detector on the market today. And the fastest.
Swap sensor tips within seconds and never worry about adjusting sensitivity
levels–it's taken care of automatically–even where high levels of
background vapors or refrigerants are present. The refrigerant sensor tip is finely tapered to 0.2 inch diameter–so you can get in between coils and
fittings, gaining access to hard to reach areas.
The Informant2 Refrigerant Gas Leak Detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of refrigerant gases.
Features:
Lightweight and ergonomically designed
Swap sensor tips in seconds
Microprocessor controlled for accuracy and reliability
Sequential flashing probe tip, dual LED displays and loud tick rate indicates relative
concentration levels
Response time is two-tenths of one second
Probe length adjustable from 3" to 20"
Spec Summary:
Sensing Element:
Heated Diode – U.S. Patent No. 5,932,176
Refrigerants Detected:
All CFC, HCFC and HFC
refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A,
R-408A,
R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or
Bromine gas)
Alarm Sensitivity:
Less than 0.25 oz/year of R134a (hardest
to detect refrigerant)
Alarm Types:
Audible, dual visual LEDs, and flashing
probe tip
Power Source:
Four (4) AA disposable alkaline batteries
included.
Warm-up Time:
10 seconds
Response Time:
Instantaneous
Battery Life:
4-5 hours, under typical intermittent
operation.
Probe:
20" (50.8 cm) maximum length, fully
extended; 3" (7.62 cm) if wrapped around instrument.
Includes LED indicator.
Size:
1.75W (4.45 cm) x 9.62L (24.43 cm) x
2.25"H (5.72 cm)
Click the link(s) above to open the document(s) for this item. Should you wish to
download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here