Bacharach PCA® 2 Combustion Gas Analyzer (O2, CO, SO2)
This Bacharach PCA® 2 Combustion Gas Analyzer is ideal for service technicians and boiler contractors!
Item #: 167019
Manufacturer: Bacharach Incorporated
Manufacturer Item #: 24-8353
Your Price $2,570.00
Features & Applications:
This Bacharach PCA 2 combustion analyzer is the perfect tool for service technicians and boiler contractors who need to ensure safe operating conditions, determine combustion efficiency, or perform emissions testing in combustion applications. The PCA®2 directly measures and displays flue gas Oxygen (O2), Carbon Monoxide (CO), Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature and Sulfur Dioxide (SO2). Simultaneously, the PCA®2 calculates and displays combustion efficiency (EFF), Excess Air (EA), Carbon Dioxide (CO2), Oxygen reference values. It features a warm up time of only 60 seconds. Includes four AA batteries.
Features:
- Smart Sensors
- Field replaceable
- Pre calibrated
- Easy access
- Quick and accurate response
- Measures 3 Gases Simultaneously
- Standard - O2, CO, SO2
- Automatic CO Overrange Protection
- Versatile Power Management
- 4 AA alkaline disposable batteries
- Graphic Display
- 160 x 160 graphic liquid crystal display
- Easy to read
- Backlit
- Zoom
Specifications:
| Measurement Ranges: | ||||
| Primary/Ambient Air Temperature: | -4° to 999°F | |||
| Stack Temperature: | -4° to 2192°F | |||
| Oxygen: | 0 to 20.9% | |||
| Carbon Monoxide (H2 comp): | 0 to 4,000 ppm | |||
| Sulfur Dioxide: | 0 to 5,000 ppm | |||
| Pressure/Draft: | -72 to +72 inwc | |||
| Calculated Ranges: | ||||
| Combustion Efficiency: | 0.1 to 100% | |||
| Excess Air: | 1.0 to 250% | |||
| Carbon Dioxide (dry basis): | 0 to fuel dependent maximum | |||
| CO referenced to % O2: | 0 to 9,999 ppm | |||
| SO2 referenced to % O2: | 0 to 9,999 ppm | |||
| Accuracy: | ||||
| Oxygen: | ± 0.3% O2 (on flue gas) | |||
| Stack or Flue Gas Temperature: |
|
|||
| Primary-air/Ambient Temperature: | ± 2°F between 32 and 212°F (± 1°C between 0 and 100°C) |
|||
| Pressure/Draft: |
|
|||
| CO: |
|
|||
| SO2: | ± 5% of reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2 | |||
| Memory: | 500 complete combustion test records | |||
| Logged Memory: | 500 complete logged combustion test records | |||
| Size: | 9"H x 3"W x 2.5" (22.9 cm x 7.6 cm x 6.3 cm) | |||
| Weight: | 1.4 lbs (0.6 kg) | |||
| Power Source: | Four disposable AA alkaline batteries | |||
| Display: | 160 x 160 (2.5 in x 2.5 in) Graphic Liquid Crystal Display | |||
| Warm Up Time: | 60 second total warm up time (sensors are checked and autozeroed during warm up) | |||