UEi Phoenix II HVAC/R Clamp Meter

UEi Phoenix II HVAC/R Clamp Meter
Item #: E510-2790 (DISC)
Manufacturer: UEi
Manufacturer Item #: DL279
Product Type: Clamp Meters
Your Price: $129.95
UEi Phoenix II HVAC/R Clamp Meter is all you need for HVAC/R applications!
Features & Applications:

UEi Phoenix II HVAC/R Clamp Meter possess all the full ranging features of the Phoenix II (DL279) such as AC/DC Volts, AC Amps, AC/DC Micro Amps, capacitance, frequency, duty cycle and resistance and adds features like temperature, non-contact voltage, and a dual screen display for multiple readings.

With the innovative CH2* - The Hook, a change of clamp heads allows users to transform the Phoenix enabling them to work in tight spaces at a new level of efficiency and safety.

The Phoenix is backed by a three year limited lifetime warranty, and supported by on-staff technical service professionals, a phone call or e-mail away.

*CH2 – The Hook, extended clamp head sold separately (#E510-2891) .

Features:

  • Detachable clamp head
  • Worklight
  • Magnetic mount
  • Large backlight display
  • Test lead storage
  • Test lead holder on clamp head
  • Data hold
  • Auto Off
  • Three year limited warranty

Functions:

  • 750V AC/1000V DC
  • 400A AC
  • 2000µA AC/DC
  • 40M Ohms resistance/continuity
  • 4000µF capacitance
  • -40 ~ 752°F Temperature (K type)
  • Frequency/Duty cycle
  • Non-Contact Voltage
  • Diode
  • Min/Max display
  • Accessories included:
    • Test leads
    • K type probe (no adapter required)
    • Zippered Case
    • 2 AAA batteries

Safety Compliance:

  • CATIII 600V, CATII 1000V

Spec Summary:

AC Amps Measurement - Jaw input (45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
40A 0.01A ±2.9% +15 dgts 600V
400A 0.1A ±1.9% +8 dgts

DC Low Amps Measurement (test lead input)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±1.2% +3 dgts 2000µA / 600V
2000µA 0.1µA

AC Low Amps Measurement (test lead input, 45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±2.0% +5 dgts 2000µA / 600V
2000µA 0.1µA ±1.5% +5 dgts

DC Volts Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±0.5% +4 dgts 600V
4V 1mV
40V 10mV
400V 100mV
1000V 1V ±0.8% +10 dgts

AC Volts Measurement (45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
4V 1mV ±2.0% +5 dgts 600V
40V 10mV
400V 100mV
750V 1V

Ohms Measurement
Range Resolution Accuracy Overload Protection
400 Ohms 100m Ohms ±1.0% +4 dgts 600V
4k Ohms 1Ohms
40k Ohms 10 Ohms
400k Ohms 100 Ohms
4M Ohms 1k Ohms
40M Ohms 10k Ohms ±2.0% +4 dgts


Diode Test
Range Open Circuit Voltage Test Current (typical) Overload Protection
2.0V < 3.0V DC 0.25mA 600V

Capacitance Measurement
Range Resolution Accuracy Overload Protection
40nF 0.01nF ±3.5% +6 dgts 600V
400nF 0.1nF
4µF 0.001µF
40µF 0.01µF
400µF 0.1µF
4000µF 1µF

Temperature Measurement
Range Resolution Accuracy Overload Protection
-30° to 14°F 0.1°F ±5.4°F 30V
15° to 752°F 0.1°F ±1.0% +3.6°F

-30° to -10°C 0.1°C ±3.0°C
-9° to 400°C 0.1°C ±1.0% +2.0°C

Frequency Measurement
Range Resolution Accuracy Overload Protection
9.999Hz 0.001Hz ±0.1% +4 dgts 600V
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
Minimum frequency: 0.5Hz, DC V offset should be zero
Sensitivity: > 1.0V rms

Duty (%) Cycle Measurement
Range Accuracy Overload Protection
01. to 99.9% ±(0.2% per kHz +0.1%) +5 count 600V
0.5Hz to 100kHz (pulsewidth > 2usec)

Continuity Measurement
Open Circuit voltage <2.7V Overload Protection
Threshold Approximately <20 Ohms 600V

Accessories are also Available:

E510-2891 - UEi Phoenix Extended Clamp Meter Head

Close Window