Fluke's Insulation Multimeter is packed with valuable features to help you on the job!
Features & Applications:
The Fluke 1587 Insulation Multimeter combines a digital insulation tester with a full-featured, True RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switchgear, the easy-to-use Fluke 1587 Insulation Multimeter is ideally suited to help you with your tasks.
Features:
- Large display with backlight
- Insulation test: 0.01 Mohm to 2 Gohm
- Insulation test voltages for many applications: 50V, 100V, 250V, 500 V, 1000 V
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Autodischarge of capacitive voltage
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (ohms), Continuity
- Capacitance, diode test, temperature, Min/Max, frequency (Hz)
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
- Included accessories: Remote probe, test leads and probes, alligator clips
- K-type thermocouple
- Filter for motor drive measurements
- Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
- Rugged, utility hard case allows you to bring everything you need for the job
- 3 year manufacturer warranty
Spec Summary:
| Specifications |
|
Voltage DC: |
Maximum Voltage: 1000V
Accuracy: ±(0.09%+2)
Maximum Resolution: 0.001V |
Voltage AC: |
Maximum Voltage: 1000V
Accuracy: ±(2%+3)
AC Bandwidth: 5kHz
with low pass filter; 3db @ 800 Hz |
Current DC: |
Maximum Amps: 400mA
Amps Accuracy: ±(0.2%+2)
Maximum Resolution: 0.01 mA |
Current AC: |
Maximum Amps: 400mA
Amps Accuracy: ±(1.5%+2)
1 kHz bandwidth
Maximum Resolution: 0.01 mA |
Resistance: |
Maximum Resistance: 50 Mohms
Accuracy: ±(0.9%+2)
Maximum Resolution: 0.1ohms |
Capacitance: |
Maximum Capacitance: 9,999 µF
Accuracy: ±(1.2%+2)
Maximum Resolution: 1 nF |
Frequency: |
Maximum Frequency: 100 kHz
Accuracy: ±(0.1%+1)
Maximum Resolution: 0.01 Hz |
Temperature Measurement: |
-40.0 °F to 998 °F
-40.0 °C to 537 °C
excluding probe |
Diode Test: |
Range: 6V
Resolution: 1 mV
Accuracy: ±(2%+1) |
| Insulation Test |
|
Minimum Test Current @
1kŁ/V: |
1mA |
Test Voltages: |
50, 100, 250, 500, 1000 V |
Maximum Resistance per
Test Voltage: |
50V:
100V:
250V:
500V:
1000V: 2 Gohms |
Maximum Resolution per
Test Voltage: |
50V: 0.01 Mohms
100V: 0.01 Mohms
250V: 0.1 Mohms
500V: 0.1 Mohms
1000V: 0.1 Mohms |
Accuracy per Test
Voltage: |
50V: ±(3 % + 5)
100V: ±(3 % + 5)
250V: ±(1.5 % + 5)
500V: ±(1.5 % + 5)
1000V: ±(1.5 % + 5)
to 600 Mohms, ±(10 % + 3)
above 600 Mohms |
| Environmental Specifications |
|
Operating temperature: |
-4 to 131°F (20 to +55 °C) |
Storage temperature: |
-40 to 140°F (-40 to +60°C) |
Humidity (Without
Condensation): |
0 - 95% (10 30 °C)
0 - 75% (30 40 °C)
0 - 40% (40 55 °C) |
Operating Altitude: |
6,561.6 ft ( 2000 m) |
| Safety Specifications |
|
Overvoltage category |
Complies with ANSI/ISA 82.02.01
(61010-1) 2004,
CAN/CSA-C22.2
NO. 61010-1-04, and IEC/EN
61010-1 2nd Edition for measurement
CAT III
1000 V and CAT IV 600 V |
Agency approvals: |
2000 m CAT III 1000 V, CAT IV 600 V;
3000 m CAT II 1000 V, CAT III 600 V |
| Mechanical & General Specifications |
|
Size: |
7.9" x 3.9" x 1.9"
[203 x 100 x 50 mm] (with holster) |
Weight: |
624 g |
Warranty: |
3 years |
Battery life Alkaline: |
Meter use: 1000 hours
Insulation test use: Meter can perform
at least 1000 insulation tests with fresh
alkaline batteries at room temperature.
These are standard tests of 1000 V into
1 Mohms with a duty cycle of 5 seconds on
and 25 seconds off.
|
IP Rating: |
IP40 |
|