Get the most useful capabilities of a power quality analyzer, multimeter and scope with the Fluke 43B Power Quality Analyzer
Features & Applications:
The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems, and diagnose equipment failures. All these powerful features are housed in a rugged handheld package.
Features:
- NiMH Battery provides extended operating time of 6.5 hours
- Combines the most useful capabilities of a power quality analyzer, multimeter and scope
- Calculates 3-phase power on balanced loads, from a single-phase measurement
- Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
- Monitoring functions help track intermittent problems and power system performance
- Records two selectable parameters for up to 16 days
- 20 measurement memories to save/recall screens and data with cursor readings
- FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
- Measures resistance, diode voltage drop, continuity, and capacitance
- Users/applications manual and power quality video to help answer tough questions
- Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
- 3 year warranty on the Fluke 43B, 1 year on accessories
Spec Summary:
| Specifications |
|
Input Characteristics: |
Input impedance: 1 MΩ, 20 pF
Voltage rating: 600V rms, CAT III |
V/A/Hz Display: |
True-rms voltage (ac + dc)
Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V*
Accuracy: ±(1% + 10 counts)
True-rms current (ac + dc)
Ranges: 50.00 A, 500.0 A, 5.000 kA , 50.00 kA, 1250 kA
Accuracy: ±(1% + 10 counts)
Frequency ranges: 10.0 to 15.0 kHz
Accuracy: ±(0.5% + 2 counts)
CF Crest factor Ranges: 1.0 - 10.0
Accuracy: ±(5% + 1 count) |
Power Display: |
Watts, VA, VAR
|
|
1-phase and 3-phase,
3 conductor balanced loads |
Ranges: 250 W - 1.56 GW
Accuracy: ±(4% + 4 counts) Fundamental Power
Accuracy: ± (2 % + 6 counts) Total Power
PF Power Factor
Range: 0 - 1.0
Accuracy: ±0.04
DPF Displacement Power
Factor, Cos .F
Range: 0.25 - 0.9
Accuracy: ±0.04
Range: 0.90 - 1.0
Accuracy: ±0.03
H2 Frequency Fundamental
Ranges: 40.0 to 70.0 Hz
Accuracy: ±(0.5% + 2 counts) |
Harmonics Display: |
Voltage, Current,
Frequency
Ranges: Fundamental to 51st harmonic
Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts)
2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts)
Frequency Fundamental
Ranges: 40 Hz to 70 Hz
Accuracy: ±0.25 Hz
Phase Range: V, A (between Fundamental & Harmonics)
Accuracy: ±3º to ±15º
Range: W (between Voltage Fundamental & Current Harmonics)
Accuracy: ±5º to ±15º
K-factor (Current and Power)
Range: 1.0 to 30.0
Accuracy: ±10%
THD Total Harmonic Distortion
Range: 0.00 - 99.99
Accuracy: ±(3% + 8 counts) |
Sags and Swells: |
Recording times: 4 min to 16 days (selectable)
Vrms Actual, Vrms max,
min(AC + DC)
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: Readings ±(2% +10 counts);
Cursor readings ± (2% + 12 counts)
Arms Actual, Arms max, min (AC + DC)
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(2% +10 counts) |
Transient Capture: |
Minimum pulse width: 40 ns
Useful bandwidth input 1: DC to 1 MHz
Number of transients: 40
Voltage threshold settings: 20%, 50%,
100%, 200% above or below reference
Reference signal: After START, the Vrms and frequency
of the signal are measured. From
these data a pure sinewave
is calculated as reference for threshold
setting.
Vpeak min, Vpeak max at cursor: 0 V, 25 V, 50 V, 125 V,
250 V, 500 V, 1250 V
Accuracy: ±5% of full scale |
R, C, Diode, Continuity: |
Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ,
500.0 kΩ, 5.000 MΩ, 30.00 MΩ
Resistance accuracy: ±(0.6% + 5 counts)
Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF,
50.00 µF, 500.0 µF
Capacitance accuracy: ±(2% + 10 counts)
Diode Ranges: 0 to 3.000 V
Accuracy: ±(2% + 5 counts)
Continuity: Beeper on at < 30 Ω ± 5 Ω
Max current: 0.5 mA
Temperature: °F or °C |
Inrush Current: |
Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Cursor readings: A peak max at cursor 1 and cursor 2
Accuracy: ±5% of full scale
Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250)
Accuracy: ±(0.2% + 2 pixels) |
Temperature (with
accessory): |
Range: -148 - 752°F (-100 - 400°C)
Accuracy: ±(0.5% + 5 counts) |
Scope Display: |
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty
cycle, phase, pulse width, crest factor
Time ranges: 20 ns/div to 60 s/div
Max sampling rate: 25 MS/s
Bandwidth
Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s
Current Clamp
Coupling: AC, DC (10 Hz - 3 dB)
Vertical sensitivity: 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
Timebase modes: Normal, roll, single
Pre-trigger: Up to 10 divisions
Trigger Source: Input 1 or Input 2 or automatic selection
Trigger Mode: Automatic Connect-and-View, Free Run,
and Single Shot
Connect-and-View: Advanced automatic triggering that
recognizes signal patterns
Automatically adjusts triggering, timebase and amplitude
and displays stable pictures |
Memories: |
20 (screens, settings, data) |
Recording: |
Recording times: 4 min to 16 days (selectable)
Parameters: Choose one or two parameters from one of
the groups below:
Volts/Ampères/Hertz
Power: Watts, VA, VAR, PF, DPF, Frequency
Harmonics, THD, Volts (Fund. & Harmonic), Ampères
(F&H) Watts(F&H)
Frequency (H), %(H) of total, Phase(H), KF
Temperature
Resistance: Resistance, Diode, Continuity, Capacitance
Scope: DC Voltage, DC Current, AC Voltage, AC Current,
Frequency, Pulse Width + or -, Phase, Duty cycle + or -,
Peak max, Peak min, Peak min-max, Crest Factor |
Note: |
*Rated EN 61010-1 600 V CAT II CSA |
| Environmental Specifications |
|
Operating Temperature: |
32 to 122°F (0 to +50°C) |
| Safety Specifications |
|
Electrical Safety: |
EN 61010-1 CAT II, 600V. CSA listed |
| Mechanical & General Specifications |
|
Size: |
9.13" x 4.52" x 1.96"
(232 x 115 x 50 mm) |
Weight: |
1.1 kg |
Warranty: |
3 years |
Battery Life: |
Rechargeable NiMH pack
(charger included), 6.5 hrs
extended operating time
(continuous) |
Shock & Vibration: |
Mil 28800E, Type 3, Class III,
Style B |
Case: |
IP51 (dust, drip, waterproof) |
|