You'll enjoy a multitude of valuable features with the Amprobe Pocket Size AutoRanging Multimeter.
Features & Applications:
The Amprobe PM55A is the ultimate shirt-pocket sized
meter. Only 3/8" thick and less than
3 oz in weight with full functionality
offering ac and dc voltage to 600 V,
ac and dc current to 2000 µA, resistance
to 6 Megohm, capacitance to
2000 µF, frequency to 30 kHz, diode
test and continuity w/beeper. It
also offers VolTect, a built-in,
non-contact voltage detector for
ac voltages.
Another key feature is AutoTect,
which automatically selects
between ac voltage, dc voltage or
resistance measurement based on
the test point to which the leads are connected. Fully autoranging, this
meter offers nine different measurement
functions plus features that
are usually found in much more
expensive and larger meters.
The digital display is oversized
with large digits and unit icons in
the display. In spite of its size, this
meter is fully safety rated to CAT III
300 V, CAT II 600 V and is UL listed.
No other meter this small offers
such performance and high safety
ratings. Includes a silicone protective
holster, deluxe carrying case,
attached test leads, battery and
manual.
Features:
- Unique AutoTect feature directs the meter to know if it is measuring AC volts, DC volts or resistance with no user interface
- The AutoTect feature has lower input impedance, which zeros out ghost voltages
- High Input Impedance feature for measuring electronic control circuitry
- Measures ac/dc current, capacitance, frequency, continuity with beeper
- Includes Voltect, a built-in, non-contact AC voltage detector
- Complete user protection with full safety ratings of CAT III 300 V, CAT II 600 V and cULus listing
- Large oversize digital display
- Protective silicon holster included, attached test leads, battery, deluxe zippered carrying case and manual
- One-year No Hassle warranty
Spec Summary:
| Specifications |
|
RF field @ 3 V/m: |
Specified accuracy + 45 d (capacitance not specified) |
DC Voltage: |
Range: 6.000 V
Accuracy: ± (0.5 %+3 dgt)
Range: 60.00 V
Accuracy: ± (1.0 %+5 dgt)
Range: 600 V
Accuracy: 2.0 % (AutoTect Lo-Z)
Range: 600 V
Accuracy: 1.5 % + 5 dgt (Hi-Z only)
NMRR: > 30 dB @ 50 Hz/60 Hz
CMRR: > 100 dB @ DC, 50 Hz/60 Hz; Rs=1 kΩ
Input impedance: AutoTect Lo-Z V DC: 833 kΩ
(4.2 kΩ when displaying AUTO), 90 pF nom.
V DC AutoTect threshold: > +1.2 V dc or
< -0.6 V dc nominal |
AC Voltage: |
Range: 50 Hz - 60 Hz 6.000 V, 60.00 V, 450.0 V
Accuracy: ± (1.5 %+5 dgt)
Input impedance: AutoTect Lo-Z V ac: 160 kΩ,
160 pF nominal
CMRR: > 60 dB @ dc to 60 Hz, Rs=1 kΩ
Input impedance: ACV AutoTect threshold
> 1.5 V ac (50 Hz/60 Hz) nominal
Hi-Z ACV: 5 MΩ, 90 pF nominal
ACV AutoTect threshold: > 1.5 V ac
(50 Hz/60 Hz) nominal
|
Capacitance: |
Range1: 100.0 nF, 1000 nF, 10.0 µF, 100.0 µF,
2000 µF3
Range2: µF± (3.5 %+6 dgt4) |
Resistance: |
Range 5: 600.0 Ω
Accuracy: ± (2.0%+6 dgt)6
Range: 60.00 kΩ 600.0 kΩ
Accuracy: ± (1.0 %+4 dgt)
Range: 6.000 kΩ
Accuracy: ± (1.2%+6 dgt))6
Range: 6.000 MΩ
Accuracy: ± (2.0%+4 dgt)
Open circuit voltage: 0.4 V DC typical |
Frequency: |
Range7, 8: 10.00 Hz - 30.00 kHz
Accuracy: ± (0.5 %+4 dgt)
:Specified at: < 20 V Sine-rms
Range: 10.00 Hz - 999.9 Hz
Accuracy: ± (0.5 %+4 dgt)
Specified at: < 600 V Sine-rms |
DC µA Current: |
Range: 400.0 µA
Accuracy: ± (1.5 %+3 dgt)
Burden voltage: 6 mV/µA
Range: 2000 µA
Accuracy: ± (1.2 %+3 dgt)
Burden voltage: 6 mV/µA |
AC µA Current: |
Range: 400.0 µA
Accuracy: ± (2.0 %+3 dgt)
Burden voltage: 6 mV/µA
Range: 2000 µA
Accuracy: ± (1.5 %+3 dgt)
Burden voltage: 6 mV/µA |
VolTect: |
Typical voltage Bar graph indication: 15 V to 55 V
– 30 V to 85 V – – 55 V to 145 V – – – 85 V to
190 V – – – – above 120 V – – – – –
Indication: Bar graph segments & audible beep
tones proportional to field strength
Detection frequency: 50/60 Hz
Detection antenna: Top left corner of the meter |
Audible Continuity Tester: |
(600 Ω range)
Open circuit voltage: 0.4 V dc typical
Audible threshold: 50 Ω to 300 Ω |
Diode Tester: |
Test current (typical): 0.48 mA
Open circuit voltage: < 1.6 V dc |
1Additional 50.00 nF range accuracy is not specified.
2Accuracies with film capacitor or better
3Updates > 1 minute on large values
4Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approx 2.4 V
5AutoTect is for 6.000 kΩ ~ 6.000 MΩ ranges
6Add 40 dgt to specified accuracy while reading is below 20 % of range
7Sensitivity (Sine-rms): Hz in Auto-VΩ position:> 3 V
8Line-level Hz in V position: @6.000 V ac range: > 3 V; @60.00 V ac range: > 6 V; @600.0 V ac range: > 60 V
| General Specifications |
|
Display and update rate: |
3-5/6 digits 6000 counts; Updates 5 per
second nominal |
Operating Temperature: |
32 to 104°F (0 - 40°C) |
Relative Humidity: |
Max. 80 % R.H. up to 87.8°F (31°C),
decreasing linearly to
50 % R.H. at
104°F (40°C) |
Altitude: |
Operating below 2000 m |
Storage Temperature: |
-4 ~140°F (-20 ~ 60°C), < 80 % R.H.
(with battery removed) |
Temperature Coefficient: |
Nominal 0.15 x (specified accuracy)/°F (°C) @
32 ~ 64.4°F or 82.4°F ~ 104
(0 ~ 18°C or 28 ~ 40°C), or otherwise
specified |
Sensing: |
Average sensing |
Overload Protection: |
600 V dc and V ac rms |
Low Battery: |
Below approx. 2.4 V |
Power Supply: |
3 V standard button battery x 1 (IEC-CR2032;
ANSI-
NEDA-5004LC) |
Power consumption (typical): |
6 mA for voltage functions on Auto-V Ω
position & 2
mA for other functions |
Automatic Power Off (APO) timing: |
Idle for 3 minutes |
APO Consumption (typical): |
2.2 µA |
Dimensions: |
4.4" x 2.1" x 0.4" (L 113 mm x W 53 mm x H 10.2 mm) |
Weight : |
Approx. 3 oz (78 gm) |
Special features: |
AutoTect (Automatic V & Ω selection) and
VolTect (Electric Field Detection) |
Agency Approvals: |
CE, cULus |
Safety: |
Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2
No. 1010.1-92,CAT II 600 V and CAT III 300 V,
Pollution Degree 2, Class 2 E.M.C. Meets EN61326 |
|