Fluke 115 Multimeter

Fluke 115 Multimeter
Item #: E610-8790
Manufacturer: Fluke Corporation
Manufacturer Item #: 2538790
Product Type: Multimeter
Your Price: $149.95
In Stock

Look no further than the Fluke 115 Multimeter for all of your electrcial testing needs!
Features & Applications:

A compact true-rms meter for field service technicians, the Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.

Features:

  • AutoVolt: automatic ac/dc voltage selection
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated
  • Safety conformance: All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
  • Includes:
    • Multimeter
    • Holster
    • Installed 9 V battery
    • TL 75 Test leads

Spec Summary:

Specifications
Maximum voltage between
any terminal and earth ground:
600 V
Surge protection:
6 kV peak per IEC 61010-1 600 VCAT III,
Pollution Degree 2
Display:
Digital: 6,000 counts, updates 4 per second
Bar graph:
33 segments, updates 32 per second
Operating Temperature:
14 to 122°F (-10 to + 50°C)
Storage Temperature:
-40 to 140°F (-40 to + 60°C)
Battery type:
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life:
400 hours typical, without backlight
Accuracy Specifications
DC millivolts:
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 2.0% + 3
DC volts:
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Auto volts:
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms:
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms:
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity:
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω;
detectsopens or shorts of 500 μs or longer.
Ohms:
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % + 2

Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

Mechanical & General Specifications
Size:
Height: 10.875" (27.62 cm)
Length: 6.25" (15.875 cm)
Width: 2.203"(5.6 cm)
Weight:
1.34 lbs (607 g)
Warranty:
3 years
Close Window