Maximum voltage between
any terminal and earth ground: |
600 V |
Surge protection: |
6 kV peak per IEC 61010-1 600 VCAT III,
Pollution Degree 2 |
Fuse for A input: |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
Display: |
Digital: 6,000 counts, updates 4 per second |
Bar graph: |
33 segments, updates 32 per second |
Operating Temperature: |
14 to 122°F (-10 to + 50°C) |
Storage Temperature: |
-40 to 140°F (-40 to + 60°C) |
Battery type: |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life: |
400 hours typical, without backlight |
Accuracy Specifications |
|
DC millivolts: |
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 2.0% + 3 |
DC volts: |
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V |
Auto volts: |
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms: |
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms: |
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity: |
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω;
detects opens or shorts of 500 μs or longer. |
Ohms: |
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % + 2 |
Diode Test: |
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2 |
Capacitance: |
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 μF / 0.01 μF
Range/Resolution: 100.0 μF / 0.1 μF
Range/Resolution: 9999 μF / 1 μF
Range/Resolution: 100 μF to 1000 μF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 μF
Accuracy: 5% + 20% |
LoZ capacitance: |
Range: 1 nF to 500 μF
Accuracy: 10% + 2 typical |
Temperature2 (Type-K thermocouple): |
Range/Resolution: -40 to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40°F to 752 °C / 0.2 °F
Accuracy: 1% + 182 |
AC amps true-rms (45 Hz to 500 Hz): |
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution:10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A continuous overload for 30 seconds max |
DC amps: |
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution:10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A continuous overload for 30 seconds max |
Hz (V or A input)2: |
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2 |