Fluke 116 HVAC Multimeter
The Fluke 116 Multimeter for troubleshooting HVAC equipment and flame sensors
Item #: E610-8803
Manufacturer: Fluke Electronics
Manufacturer Item #: 2538803
Product Type: HVAC Multimeter
Your Price $194.95
Features & Applications:
The Fluke 116 HVAC Multimeter features an ergonomic design for improved comfort and was designed specially for use in HVAC applications. The multimeter provides True RMS measurements of temperature and microamps so that you can more efficiently troubleshoot HVAC equipment and flame sensors. View the full list of features below.
Features:
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak)
- CAT III 600 V safety rated
- Includes:
- HVAC Multimeter
- TL75 Test leads
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
Spec Summary:
| Specifications | |
| Maximum voltage between any terminal and earth ground: |
600 V |
| Surge protection: | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
| Display: | Digital: 6,000 counts, updates 4 per second |
| Bar graph: | 33 segments, updates 32 per second |
| Operating Temperature: | 14 to 122°F (-10 to + 50°C) |
| Storage Temperature: | -40 to 140°F (-40 to + 60°C) |
| Battery type: | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery Life: | 400 hours typical, without backlight |
| Accuracy Specifications | |
| DC millivolts: | Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 2.0% + 3 |
| DC volts: | Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V |
| Auto volts: | Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms: | Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms: | Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity: | Range: 600 ohms Resolution: 1 ohms Accuracy: Beeper on < 20 ohms, off > 250 ohms; detects opens or shorts of 500 µs or longer. |
| Ohms: | Range/Resolution: 600.0 ohms / 0.1 ohms Range/Resolution: 6.000 kohms / 0.001 kohms Range/Resolution: 60.00 kohms / 0.01 kohms Range/Resolution: 600.0 kohms / 0.1 kohms Range/Resolution: 6.000 Mohms / 0.001 Mohms Accuracy: 0.9 % + 1 Range/Resolution: 40.00 Mohms / 0.01 Moms Accuracy: 1.5 % + 2 |
| Diode Test: | Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2 |
| Capacitance: | Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 µF / 0.01 µF Range/Resolution: 100.0 µF / 0.1 µF Range/Resolution: 9999 µF / 1 µF Range/Resolution: 100 µF to 1000 µF Accuracy: 1.9% + 2 Range/Resolution: > 1000 ¥ìF Accuracy: 5% + 20% |
| LoZ capacitance: | Range: 1 nF to 500 µF Accuracy: 10% + 2 typical |
| Temperature2 (Type-K thermocouple): | Range/Resolution: -40 to 400 °C / 0.1 °C Accuracy: 1% + 102 Range/Resolution: -40°F to 752 °C / 0.2 °F Accuracy: 1% + 182 |
| AC µamps true-rms (45 Hz to 500 Hz): | Range/Resolution: 600.0 µA / 0.1 µA Accuracy: 1.0% + 2 |
| DC µamps: | Range/Resolution: 600.0 µA / 0.1 µA Accuracy: 1.0% + 2 |
| Hz (V or A input)2: | Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2 |
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
| Mechanical & General Specifications | |
| Size: | Height: 10.875" (27.62 cm) Length: 6.25" (15.875 cm) Width: 2.203"(5.6 cm) |
| Weight: | 1.34 lbs (607 g) |
| Warranty: | 3 years |
| Product Description: | Price: | Your Cart: | |
|---|---|---|---|
| Extended Warranty (5 yrs) | $19.95 | Add | |
| Test Lead Set | $21.95 | Add | |
| K-Type Lance Tip Thermocouple Probe | $47.95 | Add | |