Fluke 117 Electrician's Multimeter
The Fluke 117 features non-contact voltage detection to help get the job done faster.
Item #: E610-8815
Manufacturer: Fluke Electronics
Manufacturer Item #: 2538815
Product Type: Multimeter
Your Price $205.95
Features & Applications:
The 117 has the features and functions professional electricians need to get their job done. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The compact design makes it easy to hold and use one-handed. Integrated VoltAlert Technology allows testing for non-contact voltage directly from the meter to help get the job done faster. LoZ technology prevents false readings due to "ghost voltage" and helps accurately diagnose problems. Rely on the Fluke 117 to make your everyday measurements – up to 600 volts ac or dc, 40 MΩ, diode test and exceptionally fast continuity.
Features:
- VoltAlert technology for non-contact voltage detection
- AutoVolt automatic ac/dc voltage selection
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True-rms for accurate measurements on non-linear loads
- Measures 20 A (30 seconds momentary; 10 A continuous)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak) for hands free operation
- CAT III 600 V safety rated
- Included:
- Electrician’s Multimeter with Non-Contact Voltage
- TL75 Test leads
- Holster
Spec Summary:
| Maximum voltage between any terminal and earth ground: |
600 V |
| Surge protection: | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
| Fuse for A input: | 11 A, 1000 V FAST Fuse (Fluke PN 803293) |
| Display: | Digital: 6,000 counts, updates 4 per second |
| Bar graph: | 33 segments, updates 32 per second |
| Operating Temperature: | 14 to 122°F (-10 to + 50°C) |
| Storage Temperature: | -40 to 140°F (-40 to + 60°C) |
| Battery type: | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery Life: | 400 hours typical, without backlight |
| Accuracy Specifications | |
| DC millivolts: | Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 2.0% + 3 |
| DC volts: | Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V |
| Auto volts: | Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms: | Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms: | Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity: | Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
| Ohms: | Range/Resolution: 600.0 Ω / 0.1 Ω Range/Resolution: 6.000 kΩ / 0.001 kΩ Range/Resolution: 60.00 kΩ / 0.01 kΩ Range/Resolution: 600.0 kΩ / 0.1 kΩ Range/Resolution: 6.000 MΩ / 0.001 MΩ Accuracy: 0.9 % + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ Accuracy: 1.5 % + 2 |
| Diode Test: | Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2 |
| Capacitance: | Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 μF / 0.01 μF Range/Resolution: 100.0 μF / 0.1 μF Range/Resolution: 9999 μF / 1 μF Range/Resolution: 100 μF to 1000 μF Accuracy: 1.9% + 2 Range/Resolution: > 1000 μF Accuracy: 5% + 20% |
| LoZ capacitance: | Range: 1 nF to 500 μF Accuracy: 10% + 2 typical |
| Temperature2 (Type-K thermocouple): | Range/Resolution: -40 to 400 °C / 0.1 °C Accuracy: 1% + 102 Range/Resolution: -40°F to 752 °C / 0.2 °F Accuracy: 1% + 182 |
| AC amps true-rms (45 Hz to 500 Hz): | Range/Resolution: 6.000 A / 0.001 A Range/Resolution:10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A continuous overload for 30 seconds max |
| DC amps: | Range/Resolution: 6.000 A / 0.001 A Range/Resolution:10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A continuous overload for 30 seconds max |
| Hz (V or A input)2: | Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2 |
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
| Mechanical & General Specifications | |
| Size: | Height: 10.875" (27.62 cm) Length: 6.25" (15.875 cm) Width: 2.203"(5.6 cm) |
| Weight: | 1.34 lbs (607 g) |
| Warranty: | 3 years |