Features & Applications:
The Fluke 289 Industrial Multimeter Service Kit is a complete kit containing all the essential items needed for electrical maintenance. Perform your maintenance tasks quickly and safely with the included Fluke AC Current Clamp i400, a single range 400 A ac current clamp with current output via safety shrouded banana plugs. The clamp is compatible with most Fluke multimeters, and can also be used with other current measurement devices that accept 4mm-shrouded banana plugs and has an AC milliamp range. The division ratio is 1000:1.
This kit includes:
Fluke i400 AC Current Clamp:
The Fluke AC Current Clamp i400 is a single range 400 A ac current clamp with current output via safety shrouded banana plugs. The clamp is compatible with most Fluke multimeters or any other current measurement device that accepts 4mm-shrouded banana plugs and has an AC milliamp range. The division ratio is 1000:1.
Features:
- Companion to your DMM to measure up to 400 A AC
- 1mA/Amp output garantuees easy reading on you meter
- Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
- Specially designed to offer maximum utility in a very compact shape
- Take accurate current readings without breaking the circuit
- Soft non-slippery overmold handle prevents form accidental touching live wiring
- Max. conductor Ø 32 mm
Spec Summary:
| Specifications |
| Nominal current range: |
400A |
| Continuous current range: |
1 A - 400 A |
| Maximum Non-Destructive Current: |
1000 A |
| Lowest measurable current: |
1 A |
| Basic accuracy: |
2% + 0.06 A
(45-400 Hz)
(% reading + floorspec) |
| Usable frequency: |
5 Hz - 20 kHz |
| Output levels: |
1 mA/A |
| Safety Specifications |
| Safety: |
CAT IV 600 V, CAT III, 1000 V |
| Maximum voltage: |
1000 V AC rms from earth to ground,
in compliance with EN61010 |
| Mechanical & General Specifications |
| Warranty: |
1 year |
| Maximum conductor diameter: |
1.25 in. (32 mm) |
Maximum conductor size
(busbar): |
750 MCM |
| Output cable length: |
59 in. (1.5 m) |
| Shrouded banana plugs: |
Yes |
Fluke 289 True-RMS Industrial Logging Multimeter:
The Fluke 289 True-RMS Industrial Logging Multimeter is designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime.
Features:
- Large 50,000 count, ¼ VGA display with white backlight.
- Log multiple sessions or log data continuously for over 200 hours. This is useful for characterizing the performance of a design or for unattended monitoring
- i-info button on board help screens for measurement functions. Unsure about a function? Go to that function and Press the i button
- LoZ Volts. Low impedance voltage function prevents false readings due to ghost voltage. It is also the recommended mode when testing for absence or presence of live power
- Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- 50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current
- Saved measurements allow you to name and recall measurements made in the field
- Real Time Clock – for automatic time stamping of saved readings
- Field upgradeable and expandable meter lets you stay current as new capabilities are added
- Multi-lingual interface
- Min/Max/Average with Time Stamp to record signal fluctuations
- Soft keys, scroll buttons and easy navigation control access to secondary functions. Create custom displays too
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads
- Measure up to 10A (20 A for 30 seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead resistance from low ohms or capacitance measurements
- Peak capture to record transients as fast as 250 μs
- Premium test leads and alligator clips included
- Optical USB PC communication interface allows for easy PC download to document logged data with FVF software (not included)
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety rated
Spec Summary:
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Current AC |
| Accuracy |
0.61 %(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
|
| Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
|
| Resistance 10 50 Ω (2 wire connection) |
| Accuracy |
0.15 % + 20 |
| Range and resolution |
50.000 Ω |
|
| Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF Ω |
|
| Frequency |
| Accuracy |
0.005% + 1 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
|
| Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| DC mV resolution |
1 μV |
| Megohm range |
Up to 500 M |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Frequency |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
| Resistance Low Ohm |
0.001 Ω to 50.000 Ω 10 mA source |
| LoZ |
Yes |
| Low Pass Filter |
Yes |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Relative Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
|
| Electromagnetic Compatability |
|
| Vibration |
|
Random vibration per MIL-PRF-28800f Class 2 |
|
| Shock |
|
1 meter drop per IEC/EN 61010-1 2nd edition |
|
| Safety Specifications |
| Overvoltage category |
|
CAT III 1000 V / CAT IV 600 V safety rated |
|
| Agency Approvals |
|
| Mechanical & General Specifications |
| Maximum voltage between any terminal and earth ground |
1000V |
| Size |
|
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
|
| Weight |
|
| Battery Life |
100 minimum, 200 hours in logging mode |
| Battery type |
6 AA alkaline batteries, NEDA 15A IEC LR6 |