Fluke 355 AC/DC True-RMS Clamp Meter w/Continuity Beeper, 2000A
The display hold feature on the Fluke 355 True-RMS Clamp Meter allows you to capture readings even when the display can't be viewed!
Item #: 158965
Manufacturer: Fluke Electronics
Manufacturer Item #: FLUKE-355 / 2840265
Your Price $752.95
Features & Applications:
Confidently take reliable readings with the Fluke 355 True-RMS Clamp Meter. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. It also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
Features:
- Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac and 2000 A dc
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures 'power-on’ surge current with accuracy and repeatability
- High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool
- Resistance to 400K ohms coupled with a continuity beeper provides the convenience of a multimeter in a clamp meter
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
- Includes:
- 355 clamp meter
- C43 Soft carrying case
- 6 AA batteries
- TL224 1.5 m silicone rubber test leads
- TP2 Test Probes
- AC285 Alligator Clips
- User manual
- 3 year warranty
Spec Summary:
| Electrical Specifications: | ||
| Current Measurement dc and ac 10 Hz to 100 Hz: | Range: 40 A
|
Resolution: 10 mA Accuracy, A: 1.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF: 2.50 A Trigger Level for Hz Filter ON: 0.50 A |
| Range: 400 A | Resolution: 100 mA Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF: 2.5 A Trigger Level for Hz Filter ON: 2.5 A |
|
Range: 2000 A; 1400 ac rms |
Resolution: 1 A |
|
| Crest Factor (50/60 Hz): | Range: 40 A |
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A |
| Range: 400 A | Crest Factor* : 2 @ 330 A, 2.4 @ 270 A | |
| Range : 2000 A; 1400 ac rms | Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A | |
| Current Measurement ac 100.1 Hz to 1 kHz: | Range: 40 A | Resolution: 10 mA Accuracy > 10 A : 3.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF : 2.50 A Trigger Level for Hz Filter ON : 0.50 A |
| Range: 400 A | Resolution: 100 mA Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF : 2.5 A Trigger Level for Hz Filter ON : 2.5 A |
|
| Range: 2000 A; 1400 ac rms | Resolution: 1 A Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF : 8 A Trigger Level for Hz Filter ON : 8 A |
|
| Voltage measurement dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively): |
Range: 4 V | Resolution: 1 mV |
| Range: 40 V | Resolution: 10 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V |
|
| Range: 400 V | Resolution: 100 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V |
|
| Range: 600 V ac rms | Resolution: 1 V Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V |
|
| Range: 1000 V dc | Resolution: 1 V Accuracy: 1 % rdg + 5 digits |
|
| Voltage measurement ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively): |
Range: 4 V | Resolution: 1 mV Accuracy: 3 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V |
| Range: 40 V | Resolution: 10 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V |
|
| Range: 400 V | Resolution: 100 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V |
|
| Range: 600 V ac rms | Resolution: 1 V Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V |
|
| Ohms Measurement: | Range: 400 Ω | Resolution: 0.1 Ω Accuracy: 1.5 % + 5 digits |
| Range: 4 kΩ | Resolution: 1 Ω Accuracy: 1.5 % + 5 digits |
|
| Range: 40 kΩ | Resolution: 10 Ω Accuracy: 1.5 % + 5 digits |
|
| Range: 400 kΩ | Resolution: 100 Ω Accuracy: 1.5 % + 5 digits |
|
| Continuity Beeper: | On at ≤ 30 Ω Off at ≥ 100 Ω |
|
| Frequency Measurement: | Measurement Range Resolution: | 5.0 Hz to 1 kHz 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
| Accuracy – 5.0 Hz to 100 Hz: | 0.2 % + 2 counts | |
| Accuracy – 100.1 Hz to 1 kHz: | 0.5 % + 5 counts | |
| Trigger level: | Refer to current and voltage tables | |
*Add 2 % to error spec for CF > 2
| General Specifications: | |
| Batteries: | Six 1.5 V AA NEDA 15 A or IEC LR6 |
| Battery life (with typical usage, backlight off): | 100 hours |
| Test leads: | Rated to 1000 V |
| Weight: | .814 kg (1.8 lb) |
| Jaw size: | 58 mm (2.28 in) |
| Dimensions (LxWxD): | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
| Safety rating: | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
| Environmental Specifications: | ||
| Operating Temperature: | 32 °F to + 122 °F (0 °C to +50 °C) | |
| Storage Temperature: | -4 °F to 140 °F (-20 °C to +60 °C) | |
| Operating Humidity: | 0 to 95% (non-condensing) | |
| Operating Altitude: | 2000 m | |
| Storage Altitude: | 10,000 m | |
| IP Rating: | 42 (indoor use only) | |
| Drop Test Requirements: | 1 m | |
| EMI, RFI, EMC: | FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 | |
| Temperature Coefficients: | Current: |
0.1 % of reading per °C outside 22 °C to 24 °C |
| Voltage: | 0.1 % of reading per °C outside 22 °C to 24 °C | |