| Electrical Specifications: |
| Current Measurement dc and ac 10 Hz to 100 Hz: |
Range: 40 A
|
Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A |
| Range: 400 A |
Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A |
Range: 2000 A; 1400 ac rms
|
Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
|
| Crest Factor (50/60 Hz): |
Range: 40 A
|
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A |
| Range: 400 A |
Crest Factor* : 2 @ 330 A, 2.4 @ 270 A |
| Range : 2000 A; 1400 ac rms |
Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A |
| Current Measurement ac 100.1 Hz to 1 kHz: |
Range: 40 A |
Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A |
| Range: 400 A |
Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A |
| Range: 2000 A; 1400 ac rms |
Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A |
Voltage measurement dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively): |
Range: 4 V |
Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
|
| Range: 40 V |
Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V |
| Range: 400 V |
Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
| Range: 600 V ac rms |
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
| Range: 1000 V dc |
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits |
Voltage measurement ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively): |
Range: 4 V |
Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V |
| Range: 40 V |
Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V |
| Range: 400 V |
Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
| Range: 600 V ac rms |
Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V |
| Ohms Measurement: |
Range: 400 Ω |
Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits |
| Range: 4 kΩ |
Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits |
| Range: 40 kΩ |
Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits |
| Range: 400 kΩ |
Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits |
| Continuity Beeper: |
On at ≤ 30 Ω
Off at ≥ 100 Ω |
| Frequency Measurement: |
Measurement Range Resolution: |
5.0 Hz to 1 kHz
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
| Accuracy – 5.0 Hz to 100 Hz: |
0.2 % + 2 counts |
| Accuracy – 100.1 Hz to 1 kHz: |
0.5 % + 5 counts |
| Trigger level: |
Refer to current and voltage tables |
| Environmental Specifications: |
| Operating Temperature: |
32 °F to + 122 °F (0 °C to +50 °C) |
| Storage Temperature: |
-4 °F to 140 °F (-20 °C to +60 °C) |
| Operating Humidity: |
0 to 95% (non-condensing) |
| Operating Altitude: |
2000 m |
| Storage Altitude: |
10,000 m |
| IP Rating: |
42 (indoor use only) |
| Drop Test Requirements: |
1 m |
| EMI, RFI, EMC: |
FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
| Temperature Coefficients: |
Current:
|
0.1 % of reading per °C outside 22 °C to 24 °C |
| Voltage: |
0.1 % of reading per °C outside 22 °C to 24 °C |