Fluke 43B Power Quality Analyzer
Get the most useful capabilities of a power quality analyzer, multimeter and scope with the Fluke 43B Power Quality Analyzer
Item #: E605-43B3
Manufacturer: Fluke Electronics
Manufacturer Item #: 43B/003
Product Type: Power Analyzers
Your Price $3,020.95
Features & Applications:
The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems, and diagnose equipment failures. All these powerful features are housed in a rugged handheld package.
Features:
- NiMH Battery provides extended operating time of 6.5 hours
- Combines the most useful capabilities of a power quality analyzer, multimeter and scope
- Calculates 3-phase power on balanced loads, from a single-phase measurement
- Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
- Monitoring functions help track intermittent problems and power system performance
- Records two selectable parameters for up to 16 days
- 20 measurement memories to save/recall screens and data with cursor readings
- FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
- Measures resistance, diode voltage drop, continuity, and capacitance
- Users/applications manual and power quality video to help answer tough questions
- Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
- 3 year warranty on the Fluke 43B, 1 year on accessories
Spec Summary:
| Specifications | ||
| Input Characteristics: | Input impedance: 1 MΩ, 20 pF Voltage rating: 600V rms, CAT III |
|
| V/A/Hz Display: | True-rms voltage (ac + dc) Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V* Accuracy: ±(1% + 10 counts) True-rms current (ac + dc) Ranges: 50.00 A, 500.0 A, 5.000 kA , 50.00 kA, 1250 kA Accuracy: ±(1% + 10 counts) Frequency ranges: 10.0 to 15.0 kHz Accuracy: ±(0.5% + 2 counts) CF Crest factor Ranges: 1.0 - 10.0 Accuracy: ±(5% + 1 count) |
|
| Power Display: | Watts, VA, VAR |
|
| 1-phase and 3-phase, 3 conductor balanced loads |
||
| Ranges: 250 W - 1.56 GW Accuracy: ±(4% + 4 counts) Fundamental Power Accuracy: ± (2 % + 6 counts) Total Power PF Power Factor Range: 0 - 1.0 Accuracy: ±0.04 DPF Displacement Power Factor, Cos .F Range: 0.25 - 0.9 Accuracy: ±0.04 Range: 0.90 - 1.0 Accuracy: ±0.03 H2 Frequency Fundamental Ranges: 40.0 to 70.0 Hz Accuracy: ±(0.5% + 2 counts) |
||
| Harmonics Display: | Voltage, Current, Frequency Ranges: Fundamental to 51st harmonic Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts) 2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts) 32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts) Frequency Fundamental Ranges: 40 Hz to 70 Hz Accuracy: ±0.25 Hz Phase Range: V, A (between Fundamental & Harmonics) Accuracy: ±3º to ±15º Range: W (between Voltage Fundamental & Current Harmonics) Accuracy: ±5º to ±15º K-factor (Current and Power) Range: 1.0 to 30.0 Accuracy: ±10% THD Total Harmonic Distortion Range: 0.00 - 99.99 Accuracy: ±(3% + 8 counts) |
|
| Sags and Swells: | Recording times: 4 min to 16 days (selectable) Vrms Actual, Vrms max, min(AC + DC) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts) Arms Actual, Arms max, min (AC + DC) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts) |
|
| Transient Capture: | Minimum pulse width: 40 ns Useful bandwidth input 1: DC to 1 MHz Number of transients: 40 Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting. Vpeak min, Vpeak max at cursor: 0 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale |
|
| R, C, Diode, Continuity: | Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ Resistance accuracy: ±(0.6% + 5 counts) Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF Capacitance accuracy: ±(2% + 10 counts) Diode Ranges: 0 to 3.000 V Accuracy: ±(2% + 5 counts) Continuity: Beeper on at < 30 Ω ± 5 Ω Max current: 0.5 mA Temperature: °F or °C |
|
| Inrush Current: | Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A Cursor readings: A peak max at cursor 1 and cursor 2 Accuracy: ±5% of full scale Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels) |
|
| Temperature (with accessory): |
Range: -148 - 752°F (-100 - 400°C) Accuracy: ±(0.5% + 5 counts) |
|
| Scope Display: | Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor Time ranges: 20 ns/div to 60 s/div Max sampling rate: 25 MS/s Bandwidth Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp Coupling: AC, DC (10 Hz - 3 dB) Vertical sensitivity: 5 mV/div to 500V/div Vertical resolution: 8 bit (256 levels) Record length: 512 samples per channel Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel) Timebase modes: Normal, roll, single Pre-trigger: Up to 10 divisions Trigger Source: Input 1 or Input 2 or automatic selection Trigger Mode: Automatic Connect-and-View, Free Run, and Single Shot Connect-and-View: Advanced automatic triggering that recognizes signal patterns Automatically adjusts triggering, timebase and amplitude and displays stable pictures |
|
| Memories: | 20 (screens, settings, data) | |
| Recording: | Recording times: 4 min to 16 days (selectable) Parameters: Choose one or two parameters from one of the groups below: Volts/Ampères/Hertz Power: Watts, VA, VAR, PF, DPF, Frequency Harmonics, THD, Volts (Fund. & Harmonic), Ampères (F&H) Watts(F&H) Frequency (H), %(H) of total, Phase(H), KF Temperature Resistance: Resistance, Diode, Continuity, Capacitance Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor |
|
| Note: | *Rated EN 61010-1 600 V CAT II CSA | |
| Environmental Specifications | |
| Operating Temperature: | 32 to 122°F (0 to +50°C) |
| Safety Specifications | |
| Electrical Safety: | EN 61010-1 CAT II, 600V. CSA listed |
| Mechanical & General Specifications | |
| Size: | 9.13" x 4.52" x 1.96" (232 x 115 x 50 mm) |
| Weight: | 1.1 kg |
| Warranty: | 3 years |
| Battery Life: | Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous) |
| Shock & Vibration: | Mil 28800E, Type 3, Class III, Style B |
| Case: | IP51 (dust, drip, waterproof) |
| Product Description: | Price: | Your Cart: | |
|---|---|---|---|
| Carrying Case | $35.95 | Add | |
| Test Lead Set | $61.95 | Add | |
| Heavy Duty Test Leads | $27.95 | Add | |
| Alligator clip set | $31.95 | Add | |
| Small Size 200AMP Current Clamp w/ BNC | $204.95 | Add | |
| 3000 AMP AC Current Clamp | $540.95 | Add | |
| Large Alligator Clips | $18.95 | Add | |
| Test Lead Extension set | $22.95 | Add | |
| Electrical Tester | $62.95 | Add | |
| Insulated Silicone Test Leads | $22.95 | Add | |
| Premium test lead set | $21.95 | Add | |
| Industrial test probes | $14.95 | Add | |
| Lantern Tip Probes | $14.99 | Add | |
| Hard Rolling Case | $498.95 | Add | |
| Tool Bag | $81.95 | Add | |
| Thermocouple Module | $116.95 | Add | |