Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
Now you can carry one tool to test all temperature
sensors and transmitters in your plant. The Fluke
724 can measure and source 12 thermocouple types
and seven RTD types, plus volts and ohms. The 724
even handles high-speed pulsed RTD circuits and
provides loop power.
The dual line measure/source display lets you source temperature and view loop current at the same time. And with its simple, "no menus" controls, the Fluke 724 is easy to operate, too.
Features:
Easy to read dual display lets you view input and output simultaneously
Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
Perform fast linearity tests with 25% and 100% steps
Execute remote tests with auto step and auto ramp
Power transmitters during test using loop power supply with simultaneous mA measurement
Store frequently-used test setups for later use
Compact, streamlined shape makes it easy to carry
Rugged, reliable design stands up to field use
Backlight lets you work in poor light
Large battery capacity of four AA cells
Battery door for easy changes
Included:
Fluke 724 Temperature Calibrator
TL75 Test Leads
AC72 Test Clips
One pair of stackable test leads
Product Overview Manuals in English, French, German,
Spanish, Italian, Portuguese, Korean, Chinese and
Japanese
0.0 to 400.0 ohms: 0.1ohms (4-wire), 0.15ohms (2- and 3-wire)
401 to 1500 ohms: 0.5ohms (4-wire), 1ohms (2- and 3-wire)
1500 to 3200 ohms:1ohms (4-wire), 1.5ohms (2- and 3-wire)
15.0 to 400.0 ohms: 0.15 ohms (exc. current 0.15 to 0.5 mA),
0.1 ohms (exc. current 0.5 to 2 mA)
401 to 1500 ohms: 0.5 ohms(excitation current 0.05 to 0.8 mA)
1500 to 3200 ohms: 1 ohms(excitation current 0.05 to 0.4 mA)
RTDs and Thermocouples
Measure Accuracy:
NI-120: 0.2°C
PT-100 (385): 0.33°C
PT-100 (393): 0.3°C
PT-100 (JIS): 0.3°C
PT-200 (385): 0.2°C
PT-500 (385): 0.2°C
PT-1000 (385): 0.2°C
Resolution: 0.1°C
J: 0.7 °C
K: 0.8 °C
T: 0.8 °C
E: 0.7 °C
R: 1.8 °C
S: 1.5 °C
B: 1.4 °C
L: 0.7 °C
U: 0.75 °C
N: 0.9°C
Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK: 0.6°C
BP: 1.2°C