Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
A maintenance and calibration tool that will be at home in every instrumentation technician's tool box, the Fluke 787 ProcessMeter combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.
Features:
DMM and loop calibrator in one tool
Precision 1000V, 440 mA digital multimeter
Measure ac and dc volts, ac and dc current, resistance, continuity, and frequency
0.1% dc voltage accuracy
0.05% dc current accuracy, 1 A resolution to 30 mA
Simultaneous mA and % of scale readout
True rms ac voltage measurement to 1 kHz
Frequency measurement to 20 kHz
Min/Max/Average/TouchHold/Relative modes
Diode test and continuity beeper
DC current source/loop calibrator
20 mA current source/simulator
Simultaneous mA and % of scale readout
Manual step (25%, coarse, fine) plus auto step and auto ramp
Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
Externally accessible battery for easy battery changes
1000V overload protection on V, ohms, frequency
150V overload protection on mA, backed-up by 440 mA 1000V fuse
Designed to meet 1000 volt IEC 1010 Cat III standards
Includes:
Fluke 787 Process Meter
AC70A Alligator Clips
C81Y Protective Yellow Holster with Flex-Stand
One 9V alkaline battery
Quick Reference Guide
TL75 Safety-Designed Test lead Set
Users Manual
Spec Summary:
Specifications
Current Measurement:
Range: 0-1 A
Resolution: 1 mA
Accuracy: 0.2% + 2 LSD
Range: 0-30 mA Resolution: 0.001 mA
Accuracy: 0.05% + 2 LSD
Current Sourcing:
Range: 0-20 mA or 4-20 mA
Resolution: 0.05% of span Drive Capability: 500 Ω @ 24 mA
Frequency:
to 19.999 kHz, 0.005% + 1 LSD
Continuity:
Beeps for resistance < 100 ohms
Voltage measurement:
Range: 0-1000 V AC or DC
Resolution: 0.1 mV to 1.0 V
Accuracy: 0.1% Rdg + 1 LSD (VDC)
Resistance measurement:
to 40 MΩ, 0.2% + 1 LSD
Diode test:
2.4 V shows diode voltage drop
Environmental Specifications
Operating Temperature:
-4 to 131°F (-20 to 55°C)
Storage Temperature:
-40 to 140°F (-40 to 60°C)
Humidity (Without Condensation);
95% up to 86°F (30°C)
75% up to 104°F (40°C)
45% up to 122°F (50°C)
35% up to 131°F (55°C)
Temperature Coefficient:
0.05 x (specified accuracy) per °C (for
temperatures < 18 °C or > 28°C)
Safety Specifications
Electrical Safety:
Designed in accordance with IEC 1010-1,
ANSI/ISA S82.01-1994 and CAN/CSA
C22.2 No. 1010.1-92
Overvoltage category:
IEC 1010-1 CAT III
Maximum voltage:
1000 V rms
Mechanical & General specifications
Size:
1.25" x 3.42" x 7.36"
(32 x 87 x 187 mm)
Weight:
369 g
Batteries:
Single 9V Alkaline battery (ANSI/NEDA
1604A or IEC 6LR61)
Click the link(s) above to open the document(s) for this item. Should you wish to
download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here
to download the latest version.