Fluke 787 ProcessMeter
Get a DMM and Loop Calibrator in one tool with the Fluke 787 ProcessMeter!
Item #: P609-7870
Manufacturer: Fluke Electronics
Manufacturer Item #: Fluke-787
Product Type: Electrical Calibrator
Your Price $750.95
Purchase this product with FlukeŽ 80T-150U Universal Temperature Probe for only $206.95 more!
Features & Applications:
The Fluke 787 ProcessMeter is the ideal tool for every instrumentation technician. The ProcessMeter is a convenient combination of a DMM and a Loop Calibrator in one compact, rugged package, offered a significant savings than purchasing the two tools separately. The technology is based upon the trusted Fluke 87 DMM, but the 787 model also includes the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.
A maintenance and calibration tool that will be at home in every instrumentation technician's tool box, the Fluke 787 ProcessMeter combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution. See the full list of features below.
Features:
- DMM and loop calibrator in one tool
- Precision 1000V, 440 mA digital multimeter
- Measure ac and dc volts, ac and dc current, resistance, continuity, and frequency
- 0.1% dc voltage accuracy
- 0.05% dc current accuracy, 1 A resolution to 30 mA
- Simultaneous mA and % of scale readout
- True rms ac voltage measurement to 1 kHz
- Frequency measurement to 20 kHz
- Min/Max/Average/TouchHold/Relative modes
- Diode test and continuity beeper
- DC current source/loop calibrator
- 20 mA current source/simulator
- Simultaneous mA and % of scale readout
- Manual step (25%, coarse, fine) plus auto step and auto ramp
- Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
- Externally accessible battery for easy battery changes
- 1000V overload protection on V, ohms, frequency
- 150V overload protection on mA, backed-up by 440 mA 1000V fuse
- Designed to meet 1000 volt IEC 1010 Cat III standards
- Includes:
- Fluke 787 Process Meter
- AC70A Alligator Clips
- C81Y Protective Yellow Holster with Flex-Stand
- One 9V alkaline battery
- Quick Reference Guide
- TL75 Safety-Designed Test lead Set
- Users Manual
Spec Summary:
| Specifications | |
| Current Measurement: | Range: 0-1 A Resolution: 1 mA Accuracy: 0.2% + 2 LSD Range: 0-30 mA >Resolution: 0.001 mA Accuracy: 0.05% + 2 LSD |
| Current Sourcing: | Range: 0-20 mA or 4-20 mA Resolution: 0.05% of span >Drive Capability: 500 Ω @ 24 mA |
| Frequency: | to 19.999 kHz, 0.005% + 1 LSD |
| Continuity: | Beeps for resistance < 100 ohms |
| Voltage measurement: | Range: 0-1000 V AC or DC Resolution: 0.1 mV to 1.0 V Accuracy: 0.1% Rdg + 1 LSD (VDC) |
| Resistance measurement: | to 40 MΩ, 0.2% + 1 LSD |
| Diode test: | 2.4 V shows diode voltage drop |
| Environmental Specifications | |
| Operating Temperature: | -4 to 131°F (-20 to 55°C) |
| Storage Temperature: | -40 to 140°F (-40 to 60°C) |
| Humidity (Without Condensation); | 95% up to 86°F (30°C) 75% up to 104°F (40°C) 45% up to 122°F (50°C) 35% up to 131°F (55°C) |
| Temperature Coefficient: | 0.05 x (specified accuracy) per °C (for temperatures < 18 °C or > 28°C) |
| Safety Specifications | |
| Electrical Safety: | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 |
| Overvoltage category: | IEC 1010-1 CAT III |
| Maximum voltage: | 1000 V rms |
| Mechanical & General specifications | |
| Size: | 1.25" x 3.42" x 7.36" (32 x 87 x 187 mm) |
| Weight: | 369 g |
| Batteries: | Single 9V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61) |
| Warranty: | 3 years |
| Battery Life: | 50 hours typical (measurement), 12 hours typical (sourcing 12 mA) |
| Shock & Vibration: | Random, 2g, 5-500 Hz 1 meter drop test |