Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videos/DVDs, audiotapes and software products (once opened), forms, documents, reports, downloads, custom orders and leased items are not returnable.
Accuracy and diagnostic functions for maximum industrial productivity. The 80 Series 5 model has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems in electronics, plant automation, power distribution, and electro-mechanical equipment.
Features:
Large display digits and 2 level bright white backlight for increased visibility
Withstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits and complies with second edition ANSI and IEC electrical safety standards
Improved sleep mode for long battery life
Relative mode to remove test lead resistance from low ohms measurements
Auto and manual ranging for maximum flexibility
Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
True-rms ac voltage and current for accurate measurements on non linear signals
Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
Measure up to 1000 V ac and dc
Measure up to 10 A (20 A for 30 seconds)
10,000 uF capacitance range
Frequency to 200 kHz and % duty cycle
Peak capture to record transients as fast as 250 μs
4½ digit mode
Applications:
Motor Drives
In Plant Automation
Power Distribution
Electro-mechanical equipment
Spec Summary:
Specifications:
Voltage DC:
Maximum Voltage:1000V
Accuracy: ±(0.05%+1)
Maximum Resolution:
10 µV
Voltage AC:
Maximum: 1000V
Accuracy: ±(0.7%+2) True RMS
AC Bandwidth: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC:
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: ±(0.2%+2)
Maximum resolution: 0.01 µA
Current AC:
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA
Resistance:
Maximum Resistance: 50 MOhms
Accuracy: ±(0.2%+1)
Maximum Resolution: 0.1Ohms
Capacitance:
Maximum Capacitance: 9,999 µF
Accuracy: ±(1%+2)
Maximum Resolution: 0.01 nF
Frequency:
Maximum Frequency: 200 Khz
Accuracy: ±(0.005%+1)
Maximum Resolution: 0.01 Hz
Duty Cycle:
Maximum Duty Cycle: 99.9%
Accuracy: ±(0.2% per khz +0.1%)
Maximum Resolution: 0.1%
Click the link(s) above to open the document(s) for this item. Should you wish to
download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here