Hanna Multiparameter GPS Enabled Water Quality Meter w/ Fast Tracker Tag Identification System (TIS) - 10m Cable
This Hanna multiparameter GPS enabled water quality meter monitors up to 13 different water quality parameters
Item #: 158779
Manufacturer: Hanna Instruments Manufacturer Item #: HI 982810-01
In stock! Usually ships within 1 business day.
Our Guarantee
Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
You can download a credit application by clicking here. Please submit your completed credit application via fax or mail. Feel free to contact us at 1-800-334-9291 with any questions.
Features & Applications:
This Hanna multiparameter GPS enabled water quality meter features quick calibration, built-in barometer, measurement check, automatic recognition of pH/ORP probe and USB connectivity. Use it for on-demand or automatic logging of up to 60,000 samples with 13 measurements each. Logging interval can be set for one second to three hours. Includes probe, calibration solution, probe maintenance kit, four rechargeable NiMH batteries, power adaptor and cable, vehicle 12V outlet adaptor, five iButtons with holder, USB cable, Windows®-compatible software, instruction manual and carrying case.
Measurements from specific locations are tracked with detailed coordinate information that can be viewed immediately on the display. GPS information can be transferred to a PC using HANNA’s HI 929828 software. GPS information can also be viewed by GPS mapping software such as Google maps*. Clicking on visited locations using mapping software such as Google Maps displays measurement information. The built-in 12 channel GPS receiver and antenna guarantees a position accuracy of 30 ft (10 m).
For measuring points within a 30 ft range or where GPS signals are not available, HI 9828’s Fast Tracker is invaluable for associating measurements with their locations.
HANNA’s exclusive Fast Tracker-Tag I.D. System monitors and records data using iButton®s that can be installed at any number of sampling sites.
The HI 9828 has a graphic, backlit display that automatically sizes the digits to fit the screen and allows full configuration of each parameter measured along with on-screen graphing capability. The meter incorporates comprehensive GLP features and the downloading of data via USB connection.
Each parameter is supported by on-screen context sensitive help, both in the calibration mode and during measurement.
Designed for outdoor environments, the meter is impact resistant and waterproof meeting IP67 standards (30 minutes immersion under 1 m of water). The multi sensor probe can be left underwater (IP68 standard).
Features:
Display up to 12 parameters
Track measurement locations with GPS
Meter features IP67 and probe features IP68 waterproof protection
Exclusive Fast Tracker-Tag I.D. System simplifies test logging
Graphic LCD with backlight
Built-in barometer for DO compensation
Quick Calibration feature
Measurement check eliminates any erroneous readings
Auto recognition of pH and pH/ORP probe
Logger function records the data of all connected sensors
Log-on-demand and automatic logging (up to 60,000 samples)
Can display logged data as graphs
USB for PC connectivity
Auto-range of EC and TDS readings
Good Laboratory Practice feature with the last 5 calibrations recorded
All sensors are field replaceable
Meter accepts both alkaline and rechargeable batteries
Rugged probe with stainless steel tip has a diameter under 2 for wells and pipes
GPS (Global Positioning System) Enabled:
The new HI 9828 features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data. The GPS tracks your location using satellites to within 30 ft (10 m) so you can be sure that you return to the same location for repeated measurements.
Basic GPS Features:
GPS coordinates shown on the LCD with up to 10 measurement parameters
GPS signal strength shown on LCD
Number of satellites shown on LCD
Logged data is embedded with GPS coordinates
Advanced GPS Features:
Users can associate GPS coordinates with alphanumeric locations
Distances between current location and predefined locations are displayed arranged by distance
Memorizes last location and time should signal be lost
Track Measurement Locations:
Users can connect to GPS tracking software such as Google Maps to view locations where samples have been taken. Measurement information is shown right on the map.
PC Software:
Manages logged data from the HI 9828
Displays GPS coordinates with logged data
Automatically maps samples on your PC (internet connection required)
Shows location points on map along with measurement data
Fast Tracker Tag Identification System:
HANNA’s iButton® Tag Identification System simplifies test logging. iButton®s with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker system complements the GPS for ultimate tracking.
Specifications:
Range:
pH
0.00 to 14.00 pH
Resolution:
pH
0.01 pH
Accuracy:
pH
±0.02 pH
Range:
mV of pH input
±600.0 mV
Resolution:
mV of pH input
0.1 mV
Accuracy:
mV of pH input
±0.5 mV
Range:
ORP
±2000.0 mV
Resolution:
ORP
0.1 mV
Accuracy:
ORP
±1.0 mV
Range:
Dissolved Oxygen
0.0 to 500.0% / 0.00 to 50.00 mg/L
Resolution:
Dissolved Oxygen
0.1% / 0.01 mg/L
Accuracy:
Dissolved Oxygen
0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading
Range:
Conductivity
0.000 to 200.000 mS/cm (absolute EC up to 400 mS/cm)
Resolution:
Conductivity
Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
Accuracy:
Conductivity
±1% of reading or ±1 µS/cm whichever is greater
Range:
Resistivity
0 to 999999 Ωcm; 0 to 1000.0 kΩcm; 0 to 1.0000 MΩcm
Resolution:
Resistivity
Dependent on resistivity reading
Range:
TDS
0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)
Resolution:
TDS
Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt); Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
Accuracy:
TDS
±1% of reading or ±1 mg/L
Range:
Salinity
0.00 to 70.00 PSU (Extended Practical Salinity Scale)
Resolution:
Salinity
0.01 PSU
Accuracy:
Salinity
±2% of reading or 0.01 PSU whichever is greater
Range:
Seawater Specific Gravity
0.0 to 50.0 σt, σ0, σ15
Resolution:
Seawater Specific Gravity
0.1 σt, σ0, σ15
Accuracy:
Seawater Specific Gravity
±1 σt, σ0, σ15
Range:
Atm. Pressure
450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
±3 mmHg within ±15°C from the temperature during calibration
Range:
Temperature
-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K
Resolution:
Temperature
0.01°C; 0.01°F; 0.01K
Accuracy:
Temperature
±0.15°C; ±0.27°F; ±0.15K
Calibration:
pH
Automatic 1, 2, or 3 points with 5 memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer
Calibration:
ORP
Automatic at 1 custom point
Calibration:
Conductivity, Salinity
Automatic 1 point with 6 memorized standards (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
Calibration:
Dissolved Oxygen
Automatic 1 or 2 points at 0, 100% or 1 custom point
Calibration:
Resistivity, TDS
Based on conductivity or salinity calibration
Calibration:
Atm. Pressure
Automatic at 1 custom point
Calibration:
Temperature
Automatic at 1 custom point
Temperature Compensation:
Automatic from -5 to 55°C (23 to 131°F)
Logging Memory:
Up to 60000 samples with 13 measurements each Up to 45,000 samples with 15 measurements each (GPS)
Logging Interval:
1 second to 3 hours
Computer Interface:
USB (with HI 929828 software)
Waterproof Protection:
Meter IP67, Probe IP68
Environment:
0 to 50°C (32 to 122°F); RH 100%
Power Supply:
(4) 1.5V alkaline C cells (approx. 150 hours of continuous use without backlight) /(4) 1.2V rechargeable C cells (approx. 70 hours of continuous use without backlight)