Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
Simultaneously measures and datalogs multiple parameters such as CO, CO2, Temperature, Relative Humidity.
Features:
Simultaneously measures and data log multiple parameters such as: CO, CO2, Temperature, Relative Humidity, to monitor indoor air quality conditions.
Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air.
Built-in memory allows user to store multiple point measurements. o Equipped with RS232C terminal.
Benefits:
Easy user calibration with built-in calibration function.
Capable to continuously monitor parameters via PC.
Relative Humidity and Temperature measurements help determine thermal comfort levels.
Large LCD shows multiple parameters at a glance.
No need of psychometric chart - Calculates dew point, wet bulb temperature, absolute humidity and humidity ratio!
Spec Summary:
Measuring Object
Indoor Air Quality
CO
Range
0~500PPM
Accuracy
+/-3% of reading or +/-3PPM whichever is greater
Resolution
0.1PPM: 0-99PPM 1PPM: 100-500 PPM
CO2
Range
0~5000PPM
Accuracy
+/-3% of reading or+/-50PPM whichever is greater
Resolution
1PPM
Temperature
Range
- 4 -140F (-20~60C)
Accuracy
+/- 1F (+/-0.5C)
Resolution
0.1F (0.1C )
Relative Humidity
Range
2~98%RH (0.1%RH step)
Accuracy
2~80%RH:±2%RH, 80~98%RH:±3%RH
Resolution
0.1%RH
Function
Normal Mode
Normal measuring (do not store and calculate the data.) Relative humidity, CO, CO2, Dew point, Wet bulb temperature, Absolute humidity and Humidity Ratio
Calculation Mode
Store the data, and calculate the maximum, minimum and average value.
% OA Mode
Measure ventilation ratio (Ask for ventilation ratio by calculating from temperature and CO2 value)
Data Output Mode
Perform re-calculation of stored data and output of data to PC and Printer.
Calibration Mode
Perform the calibration of CO and CO2.
Output
Digital
RS-232C (Baudrate:4800,9600,19200,38400bps)
Analog(Optional)
DC0~1V (Select 1 ch among CO, CO2, temperature, and relative humidity)
Power Supply
AA Battery×6(Alkaline or Ni-Cd)
AC adapter:AC100~240V (50/60Hz) (Optional)
Battery Life
Approximately 10 hours (at 77F (25?) with alkaline batteries, without RS232C)
Operating Environment
Main Body
41-104F (5~40C)
Probe
- 4 - 140F (-20~60C)
Storage Environment
- 4- 140F (-20~60C)
Standard Kit
Operation Manual×1, Mn Battery ×6, Probe stand, Calibration cap & tube, Software, RS-232C, Carrying case
Optional Accessories
Analog Output ,Serial Printer, Printer cable, AC adapter