Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
The Amprobe 5XP-A Digital Multimeter combines features and accuracy in a small device. Each 5XP-A Multimeter has built-in non-contact voltage (NCV) detection, Magne-Grip holster and CAT III safety ratings.
Features:
27 ranges/10 functions – a complete performance, general purpose digital multimeter
VolTect Non-Contact Voltage Detector lets you instantly identify dangerous AC voltage
Magne-Grip holster with magnetic strap frees both hands for work
2000-count 3-1/2 digit display
750 V ac/ 1000 V dc – highest voltage rating in this class of meter
Resistance and continuity for troubleshooting bad connections
Battery load test with 1.5 volt and 9 volt capabilities
Min/Max records minimum and maximum values
Data Hold freezes display to hold measurement reading
Spec Summary:
Specifications
DC Current:
Ranges
200 µA, 2 mA, 20 mA, 200 mA
Resolution
0.1 µA
Accuracy
± (1.5 % rdg + 1 dgt)
Input protection
315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
Burden voltage
300 mV max. (1 V max. on 200 mA range)
AC Current (45 Hz - 500 Hz):
Ranges
200 µA, 2 mA, 20 mA, 200 mA
Resolution
0.1 µA
Accuracy
± (2.0 % rdg + 5 dgts)
Input protection
315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
Burden voltage
300 mV max. (1 V max. on 200 mA range)
Resistance:
Ranges
200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
Resolution
100 mΩ
Accuracy on 200 Ω to 200 kΩ ranges
± (1.0 % rdg + 4 dgts)
Accuracy on 2 MΩ ranges
± (1.5 % rdg + 4 dgts)
Accuracy on 20 MΩ range
± (2.0 % rdg + 5 dgts)
Open circuit volts
0.3 Vdc typical, (3.0 Vdc on 200 Ω range)
Overload protection
1000 VDC or 750 VAC rms
Continuity:
Audible indication
75 Ω ± 25 Ω
Response time
100 ms
Overload protection
1000 VDC or 750 VAC rms
Diode Test:
Test current
1.0 mA (approximate)
Accuracy
± (1.5 % rdg + 3 dgts)
Resolution
1 mV
Open circuit volts
3.0 Vdc typical
Overload protection
1000 VDC or 750 VAC rms
Battery Test:
Ranges
1.5 V, 9 V
Resolution
1 mV, 10 mV
Accuracy
± (3.5 % rdg + 2 dgts)
Loaded current
150 mA typical for 1.5 V range, 5 mA typical for 9 V range
Overload protection
1000 VDC or 750 VAC rms on 9 V range, on VΩ input315 mA/1000 V fast blow ceramic fuse on 1.5 V range, on mA input
Non-Contact Voltage Indicator
Sense voltage 70 V to 600 VAC beeper chirps and big bright red LED comes on, works on all ranges
General Specifications
Display:
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
The battery icon is displayed when the battery voltage drops below theoperating level
Measurement rate:
2.5 times per second, nominal
Operating environment:
0 °C to 50 °C at <70 % R.H.
Storage temperature:
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Accuracy:
Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
Temperature coefficient:
0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
Altitude:
6561.7 feet (2000 M)
Power:
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life:
200 hours typical with carbon-zinc
Dimensions:
155 mm (H) x 72 mm (W) x 32 mm (D)
Weight:
Approx. 210 g including battery
Safety:
Designed to meet IEC 1010-1, Rev-2 CAT I 1000 V, CAT II 600 V,CAT III 300 V, class 2 and pollution deg. 2 indoor use. Complies with CE,and CSA 22.2 No. 1010-1 requirements.
Auxiliary Features:
Min/Max Records the maximum reading in a measurement, records the minimum reading in a measurementData hold Freeze the latest reading on the displaymA jack Input warning detects wrong connection
Click the link(s) above to open the document(s) for this item. Should you wish to
download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here
to download the latest version.
Amprobe 5XP-A Digital Multimeter with Voltage Detection