Professional Equipment - Your testing & inspection equipment source

View Cart My Account Fax Order
Sep 7 08
HomeAbout UsFree CatalogContact UsCustomer ServiceCatalog Express Ordering
SEARCH
Can't Find What You’re Looking For? Click Here - We Can Help You
Buy by BrandsClearance
Fluke StoreFlir StoreExtech StoreGeneral Tools Store
Print
Fluke 1735 Three-Phase Power Logger
Your Price:
$3,408.95

Fluke 1735 Three-Phase Power Logger

With the Fluke 1735 Three-Phase Power Logger, you'll be able to view graphs and generate reports!
Item #: 148353
Manufacturer: Fluke Corporation
Manufacturer Item #: 2583398 FLUKE 1735
Ships directly from manufacturer.
Shipping date will vary by manufacturer and item.
Buy Now
List Price: $3,408.95
   
 
Features & Applications:

The Fluke 1735 Three-Phase Power Logger is the ideal electrician or technician's power meter for conducting energy studies and basic power quality logging. Set the Power Logger up in seconds with the included flexible current probes and color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events.

Features:

  • Record power and associated parameters for up to 45 days
  • Monitor maximum power demand over user-defined averaging periods
  • Prove the benefit of efficiency improvements with energy consumption tests
  • Measure harmonic distortion caused by electronic loads
  • Improve reliability by capturing voltage dips and swells from load switching
  • Easily confirm instrument setup with color display of waveforms and trends
  • Measure all three phases and neutral with included 4 flexible current probes
  • View graphs and generate reports with included Power Log software
  • Compact, rugged design with IP65 case, 600 V CAT III and two-year warranty

Applications:

  • Load studies - verify electrical system capacity before adding loads
  • Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices
  • Harmonics measurements - uncover harmonic issues that can damage or disrupt critical equipment
  • Voltage event capture - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping

Spec Summary:

General
Display: ¨ù VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality: Developed, designed and manufactured according to DIN ISO 9001
Memory: 4 MB Flash memory, 3.5 MB for measuring data
Interface: RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate: 10.24 kHz
Line frequency: 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply: NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Operation time with battery: Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions: 240 mm x 180 mm x 110 mm
Weight: 1.7 kg, including battery
Ambient conditions
Working temperature range: -10 ¡ÆC to +50 ¡ÆC
Storage temperature range: -20 ¡ÆC to +60 ¡ÆC
Operating temperature range: 0 ¡ÆC to +40 ¡ÆC
Reference temperature range: 23 ¡ÆC ¡¾ 2 ¡ÆC
Note: The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient: ¡¾ 0.1 % of the measured value per ¡ÆC from the reference
Intrinsic error: Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error: Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class: C1 (IEC 654-1) -5 ¡ÆC to +45 ¡ÆC, 5% to 95% RH, no dew
Housing: Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMC
Emission: IEC/EN 61326-1:1997 class B
Immunity: IEC/EN 61326-1:1997
Safety
Safety: IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection: IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
V-rms wye measurement
Measuring range: 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
Intrinsic error: ¡¾ (0.2% of measured value + 5 digits)
Operating error: ¡¾ (0.5% of m. v. + 10 digit)
Resolution: 0.1 V
V-rms delta measurement
Measuring range: 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
Intrinsic error: ¡¾ (0.2% of m. v. + 5 digit)
Operating error: ¡¾ (0.5 % of m. v. + 10 digit)
Resolution: 0.1 V
A-rms measurement
Flexi set I ranges: 15 A/150 A/3000 A rms (at sine)
Current clamp ranges: 1 A/10 A
Resolution: 0.01 A
Ranges 150 A/3000 A and 1 A/10 A
Intrinsic error: ¡¾ (0.5 % of m. v. + 10 digit)
Operating error: ¡¾ (1 % of m. v. + 10 digit)
Ranges 15 A
Intrinsic error: ¡¾ (0.5 % of m. v. + 20 digit)
Operating error: ¡¾ (1 % of m. v. + 20 digit)
The errors of the current probes are not considered.
By using Flexi-Set
Flexi Set measuring error: ¡¾ (2% of m. v. + 10 digit)
Position influence: ¡¾ (3 % of m. v. + 10 digit)
CF (typical): 2.83
Note: When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
Measuring range: see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Specified error x (1-[PF])
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error: ¡¾ (0.7 % of m.v. +15 digit)
Resolution: 1 kW
Operating error: ¡¾ (1.5 % of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error: ¡¾ (0.7 % of m.v. +15 digit)
Resolution: 1 W to 10 W
Operating error: ¡¾ (1.5 % of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)
Intrinsic error: ¡¾ (0.7 % of m.v.+ F variation error* + 15 digit)
Resolution: 1 W to 10 W
Operating error: ¡¾ (1.5 % of m.v. + F variation error* + 20 digit)
*Frequency variation error
PF (Power factor)
Range: 0.000 to 1.000
Resolution: 0.001
Accuracy: ¡¾1 % of full scale
Frequency measurement
Measuring range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error: ¡¾ (0.2 % of m. v. + 5 digit)
Operating error: ¡¾ (0.5 % of m. v.+ 10 digit)
Resolution: 0.01 Hz
Harmonics
Measuring range: To 50th harmonic (< 50 % of nom)
Accuracy
Vm, Im, THDV, THDI: IEC 61000-4-7:2002, Class II
Vm ¡Ã 3% Vn: ¡¾ 5% Vm
Vm < 3 % Vnom: ¡¾0.15% Vnom
Im ¡Ã 10 % Inom: ¡¾ 5% Im
Im < 10 % Inom: ¡¾ 0 5% Inom
THDV: for THD < 3% ¡¾ 0.15% at Vnom
for THD ¡Ã 3% ¡¾ 5% at Vnom
THDI: for THD < 10% ¡¾ 0.5% at Inom
for THD ¡Ã 10% ¡¾ 5% at Inom
Vnom: Normal voltage range
Inom: Nominal current range
Vm and Im are measured values of harmonic m
Events
Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error: ¡¾ (1% of m.v. + 10 digit)
Operating error: ¡¾ (2% of m.v. + 10 digit)
Resolution: 0.1 V


Fluke 1735 Three-Phase Power Logger Fluke 1735 Three-Phase Power Logger

Buy Now

Enter your email address to receive our newsletter! You'll receive special offers, discounts, information on new products and more!

Submit

You are viewing...

Fluke 1735 Three-Phase Power Logger
Item#: 148353

 


ABOUT SSL CERTIFICATES
Reference Number : P1015
Electrical  Environmental Equipment  Gas Detectors  Hand Tools  HVAC  Inspection & Business Forms  Ladders  License/ Exam-Prep  Light Meters  Locators  Measuring Tools  Moisture Meters  New Products  Pest Control  Plumbing  Safety Products  Sound Meters  Specials  Thermometers  Tool Storage  Workwear  Work Lights 
Home  Cart  Request a Catalog  Contact Us  International Sales  Customer Service  Site Map  Express Shop  About Us  Alliance 
Professional Equipment is a division of Lab Safety Supply, Inc. ©2008 Lab Safety Supply, Inc.
PO Box 5197 Janesville, WI 53547-5197 USA
Phone: 1-800-334-9291  Email: info@professionalequipment.com