Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit
Record and log relative humidity, temperature & CO2 readings and graph data on your PC
Item #: M500
Manufacturer: Telaire Manufacturer Item #: 7001D Product Type: Temperature Data Loggers
In stock! Usually ships within 1 business day.
Our Guarantee
Professional Equipment and our suppliers are dedicated to providing quality products to our customers. We stand behind our commitment to quality with a satisfaction guarantee on every purchase*. If, for any reason, a customer is not satisfied with a product, they may return it within 30 days of the date purchased for a refund of the purchase price of the product(s). Returned merchandise must be in its original box, in new condition and include all instructions, and the invoice or packing slip.
*Exceptions: Videotapes, DVDs, audiotapes, computer software (once opened), animal traps (once opened), forms, reports, custom orders and leased items are not returnable. Books are returnable within 7 days of receipt. Test chemicals, once opened are not returnable. Downloads are non-refundable.
Poor air quality cannot only affect ambient air, but result in decay or damage to a structure. Equipped with infrared technology to accurately measure these components. Measure RH, temperature and CO2 with precision-enabling you to assess the conditions in the test area.
Designed for residential and commercial applications, it also has the ability to calculate and display cfm/person ventilation rate-hence
identifying ventilation-related problems such as moisture build-up, combustion gas build-up, etc. Record your findings on your computer utilizing the included graphical software and cable.
Features:
Dual beam absorption infrared
Display: LCD
Sample method: diffusion or flow through (50 – 100 ml/min)
Power supply: 4 AA batteries (not included) or 6V DC from external AC/DC adapter
(included)
Includes graphing software & computer cable
Applications:
Commercial
Residential
Procedure for using the Hobo datalogger:
Connect the 7001 to channel 3 or 4
Connect the datalogger to the computer
Start the Hobo Boxcar software
Click on the 'Launch' button to connect to the datalogger
When the Launch screen appears, click on the 'Enable/Disable Channels' button
Select the appropriate channel (3 or 4) that the 7001 is connected to
On the pull down menu next to the appropriate channel, select 'Voltage (Cable 2.5 Stereo)'
Click on the 'Apply' button
Spec Summary:
Temperature (internal sensor)
Range:
-4 to +158°F (-20 to +70°C)
Range for internal sensor when used outside of case:
-40 to +248°F (-40 to +120°C)
Accuracy:
±1.27°F (±0.7°C) at +70°F
Resolution:
0.7°F (0.4°C) at +70°F
Response time still in
air:
15 min. typical with sensor inside case; 1 min. typical with sensor outside case
Relative
humidity (user-replaceable
RH sensor)
Range:
25 to 95% RH at +80°F for intervals of > 10 seconds,
non-condensing and non-fogging
Accuracy:
±5%
Response time:
10 min. typical
in air
Sensor operating environment:
+41 to +122°F
(+5 to +50°C) non-condensing and non-fogging
Power:
External input accepts
the following sensors:
Wide range of temp sensors (TMCx-Hx series)
Split-core CTs for AC current (5 Models)
4-20 mA input cable (CABLE-4-20mA)
0-2.5 V DC input cable (Cable-2.5-Stereo)
Input range:
0 to +2.5 Volts DC
Resolution:
10 mV (8-bit)
External 2.5 Volt input 2.5 mm jack: external input ground, input, switched 2.5 Volt
output; external input ground connection is not the same
as PC interface connection ground and should not be
connected to any external ground
Accuracy:
±10 mV ±1% of reading
Out power:
+2.5 Volts DC at 2 mA, active only during measurements
Performance
CO2 Channel
Measurement Range:
0-4,000 PPM voltage output
0-10,000 PPM display
Resolution:
±1 ppm
Accuracy:
±50 ppm or ±5% of reading
(up to 1.5% or 15,000 ppm),
whichever is greater
Warm-Up Time:
<60 seconds at 72°F
Operating Conditions:
32-122°F
0-95% RH, non-condensing
Storage Temperatures:
-40 to 140°F
Calibration Interval:
12 months, offset adjustment
using single gas at 0-1000 ppm CO2.
Click the link(s) above to open the document(s) for this item. Should you wish to
download it, right click on the link and select "Save Target As..." or "Save Link As...".
If you do not have Acrobat Reader, click here
to download the latest version.
Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit