Features & Applications:
UEi Phoenix Clamp Meter provides an unprecedented list of innovative benefits
that create a value that can't be matched in the market today.
The Phoenix I offers the benefits of a full ranging DMM like: AC/DC Volts, AC
Amps, AC/DC Micro Amps, capacitance and resistance, and combines them with frequency
and duty cycle to create the most complete electrical clamp meter available.
With the innovative CH2* - The Hook, a change of clamp heads allows users to
transform the Phoenix enabling them to work in tight spaces at a new level of
efficiency and safety.
The Phoenix is supported by a three year limited lifetime warranty and experienced on-staff technical service professionals, just a phone call or e-mail away.
*CH2 – The Hook, extended clamp head sold separately (#E510-2891)
.
Features:
- Detachable clamp head
- Worklight
- Magnetic mount
- Large backlight display
- Test lead storage
- Test lead holder on clamp head
- Data hold
- Auto Off
- Three year limited warranty
Functions:
- 750V AC/1000V DC
- 400A AC
- 2000µA AC/DC
- 40M Ohms resistance/continuity
- 4000µF capacitance
- Frequency/Duty cycle
- Diode
- Min/Max display
- Accessories included:
- Test leads
- Zippered Case
- 2 AAA batteries
Safety Compliance:
Spec Summary:
AC Amps Measurement - Jaw input
(45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
400A 0.1A ±1.9% +8 dgts
DC Low Amps Measurement (test lead
input)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±1.2% +3 dgts 2000µA / 600V
2000µA 0.1µA
AC Low Amps Measurement (test lead
input, 45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±2.0% +5 dgts 2000µA / 600V
2000µA 0.1µA ±1.5% +5 dgts
DC Volts Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±0.5% +4 dgts 600V
4V 1mV
40V 10mV
400V 100mV
1000V 1V ±0.8% +10 dgts
AC Volts Measurement (45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
4V 1mV ±2.0% +5 dgts 600V
40V 10mV
400V 100mV
750V 1V
Ohms Measurement
Range Resolution Accuracy Overload Protection
400 Ohms 100m Ohms±1.0% +4 dgts 600V
4k Ohms1 Ohms
40k Ohms 10 Ohms
400k Ohms 100 Ohms
4M Ohms 1k Ohms
40M Ohms 10k Ohms ±2.0% +4 dgts |
Diode Test
Range Open Circuit Voltage Test Current (typical) Overload Protection
2.0V < 3.0V DC 0.25mA 600V
Capacitance Measurement
Range Resolution Accuracy Overload Protection
40nF 0.01nF ±3.5% +6 dgts 600V
400nF 0.1nF
4µF 0.001µF
40µF 0.01µF
400µF 0.1µF
4000µF 1µF
Frequency Measurement
Range Resolution Accuracy Overload Protection
9.999Hz 0.001Hz ±0.1% +4 dgts 600V
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
Minimum frequency: 0.5Hz, DC V offset should be zero
Sensitivity: > 1.0V rms
Duty (%) Cycle Measurement
Range Accuracy Overload Protection
01. to 99.9% ±(0.2% per kHz +0.1%) +5 count 600V
0.5Hz to 100kHz (pulsewidth > 2usec)
Continuity Measurement
Open Circuit voltage <2.7V Overload Protection
Threshold Approximately <20? 600V
|
Accessories are also Available:
E510-2891 - UEi Phoenix Extended Clamp Meter Head