Professional Equipment - Your testing & inspection equipment source

View Cart My Account Fax Order
Jul 20 08
HomeAbout UsFree CatalogContact UsCustomer ServiceCatalog Express Ordering
SEARCH
Can't Find What You’re Looking For? Click Here - We Can Help You
Buy by BrandsClearanceCatalog Express Ordering
Fluke StoreFlir StoreExtech StoreBacharach StoreMannix Store

Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit
  View Larger Image

Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit

Item #: M500
Manufacturer: Telaire
Manufacturer Item #: 7001D
Product Type: Temperature Data Loggers
Price: $715.95
In Stock

    
 
 Write a Review
Record and log relative humidity, temperature & CO2 readings and graph data on your PC

Purchase this product with Calibration Kit for Telaire® Handheld IAQ Monitor for only $305.00 more!
Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit + Calibration Kit for Telaire® Handheld Indoor Air Quality (IAQ) Monitor, 7000™ Series - Carbon Dioxide (CO2)/Temperature - GE Infrastructure Sensing    add both to cart

Features & Applications:

Poor air quality cannot only affect ambient air, but result in decay or damage to a structure. Equipped with infrared technology to accurately measure these components. Measure RH, temperature and CO2 with precision-enabling you to assess the conditions in the test area.

Designed for residential and commercial applications, it also has the ability to calculate and display cfm/person ventilation rate-hence identifying ventilation-related problems such as moisture build-up, combustion gas build-up, etc. Record your findings on your computer utilizing the included graphical software and cable.

Features:
  • Dual beam absorption infrared
  • Display: LCD
  • Sample method: diffusion or flow through (50 – 100 ml/min)
  • Power supply: 4 AA batteries (not included) or 6V DC from external AC/DC adapter (included)
  • Includes graphing software & computer cable
Applications:
  • Commercial
  • Residential

Procedure for using the Hobo datalogger:

  • Connect the 7001 to channel 3 or 4
  • Connect the datalogger to the computer
  • Start the Hobo Boxcar software
  • Click on the 'Launch' button to connect to the datalogger
  • When the Launch screen appears, click on the 'Enable/Disable Channels' button
  • Select the appropriate channel (3 or 4) that the 7001 is connected to
  • On the pull down menu next to the appropriate channel, select 'Voltage (Cable 2.5 Stereo)'
  • Click on the 'Apply' button
  • Spec Summary:

    Temperature (internal sensor)

    Range:

    -4 to +158°F (-20 to +70°C)
    Range for internal sensor when used outside of case:
    -40 to +248°F (-40 to +120°C)

    Accuracy:

    ±1.27°F (±0.7°C) at +70°F

    Resolution:

    0.7°F (0.4°C) at +70°F

    Response time still in air:

    15 min. typical with sensor inside case;
    1 min. typical with sensor outside case
    Relative humidity (user-replaceable RH sensor)

    Range:

    25 to 95% RH at +80°F for intervals of > 10 seconds,
    non-condensing and non-fogging

    Accuracy:

    ±5%

    Response time:

    10 min. typical in air

    Sensor operating environment:

    +41 to +122°F (+5 to +50°C)
    non-condensing and non-fogging
    Power:
    External input accepts the following sensors:
    Wide range of temp sensors (TMCx-Hx series)
    Split-core CTs for AC current (5 Models)
    4-20 mA input cable (CABLE-4-20mA)
    0-2.5 V DC input cable (Cable-2.5-Stereo)

    Input range:

    0 to +2.5 Volts DC

    Resolution:

    10 mV (8-bit)
    External 2.5 Volt input
    2.5 mm jack: external input ground, input, switched 2.5 Volt
    output; external input ground connection is not the same
    as PC interface connection ground and should not be
    connected to any external ground

    Accuracy:

    ±10 mV ±1% of reading

    Out power:

    +2.5 Volts DC at 2 mA, active only during measurements
    Performance
    CO2 Channel

    Measurement Range:

    0-4,000 PPM voltage output
    0-10,000 PPM display

    Resolution:

    ±1 ppm

    Accuracy:

    ±50 ppm or ±5% of reading (up to 1.5% or 15,000 ppm),
    whichever is greater

    Warm-Up Time:

    <60 seconds at 72°F

    Operating Conditions:

    32-122°F
    0-95% RH, non-condensing

    Storage Temperatures:

    -40 to 140°F

    Calibration Interval:

    12 months, offset adjustment using single gas at 0-1000 ppm CO2.



    Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit   

    Purchase this product with Calibration Kit for Telaire® Handheld IAQ Monitor for only $305.00 more!
    Relative Humidity - Temperature - Carbon Dioxide Datalogger Kit + Calibration Kit for Telaire® Handheld Indoor Air Quality (IAQ) Monitor, 7000™ Series - Carbon Dioxide (CO2)/Temperature - GE Infrastructure Sensing    add both to cart

    Our Guarantee

    Ordering from Professional Equipment is *RISK-FREE. We absolutely insist that you be completely satisfied. Take a full thirty days to review any item(s) you order. If you discover a Gas Detectors or any of our listed products is not what you expected, return it and we'll refund your money or credit your charge card for the purchase price of the product(s).

    *Exceptions: Videos/DVDs and software products (once opened), forms, documents, reports, downloads, custom orders and leased items are not returnable.


     


    ABOUT SSL CERTIFICATES
    Reference Number : P1015
    Electrical  Environmental Equipment  Gas Detectors  Hand Tools  HVAC  Inspection & Business Forms  Ladders  License/ Exam-Prep  Light Meters  Locators  Measuring Tools  Moisture Meters  New Products  Pest Control  Plumbing  Safety Products  Sound Meters  Specials  Thermometers  Tool Storage  Workwear  Work Lights 
    Home  Cart  Request a Catalog  Contact Us  International Sales  Customer Service  Site Map  Express Shop  About Us  Alliance 
    Professional Equipment is a division of Lab Safety Supply, Inc. ©2008 Lab Safety Supply, Inc.
    PO Box 5197 Janesville, WI 53547-5197 USA
    Phone: 1-800-334-9291  Email: info@professionalequipment.com