Fluke 355 AC/DC True-RMS Clamp Meter w/Continuity Beeper, 2000A

Fluke 355 AC/DC True-RMS Clamp Meter w/Continuity Beeper, 2000A
Item #: 158965
Manufacturer: Fluke Electronics
Manufacturer Item #: FLUKE-355 / 2840265
Your Price: $693.00
In Stock

The display hold feature on the Fluke 355 True-RMS Clamp Meter allows you to capture readings even when the display can't be viewed!

Features & Applications:

Confidently take reliable readings with the Fluke 355 True-RMS Clamp Meter. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. It also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

Features:

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures 'power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool
  • Resistance to 400K ohms coupled with a continuity beeper provides the convenience of a multimeter in a clamp meter
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings
  • Includes:
    • 355 clamp meter
    • C43 Soft carrying case
    • 6 AA batteries
    • TL224 1.5 m silicone rubber test leads
    • TP2 Test Probes
    • AC285 Alligator Clips
    • User manual
    • 3 year warranty

Spec Summary:

Electrical Specifications:
Current Measurement dc and ac 10 Hz to 100 Hz:

Range: 40 A

 

Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range: 400 A Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A

Range: 2000 A; 1400 ac rms

Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A

Crest Factor (50/60 Hz):

Range: 40 A

Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range: 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current Measurement ac 100.1 Hz to 1 kHz: Range: 40 A Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range: 400 A Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range: 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively):
Range: 4 V

Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range: 40 V Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 1000 V dc Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively):
Range: 4 V Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms Measurement: Range: 400 Ω Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits
Range: 4 kΩ Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits
Range: 40 kΩ Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits
Range: 400 kΩ Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits
Continuity Beeper:

On at ≤ 30 Ω

Off at ≥ 100 Ω

Frequency Measurement: Measurement Range Resolution:

5.0 Hz to 1 kHz

0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

Accuracy – 5.0 Hz to 100 Hz: 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz: 0.5 % + 5 counts
Trigger level: Refer to current and voltage tables

*Add 2 % to error spec for CF > 2

General Specifications:
Batteries: Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off): 100 hours
Test leads: Rated to 1000 V
Weight: .814 kg (1.8 lb)
Jaw size: 58 mm (2.28 in)
Dimensions (LxWxD): 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating: IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

 

Environmental Specifications:
Operating Temperature: 32 °F to + 122 °F (0 °C to +50 °C)
Storage Temperature: -4 °F to 140 °F (-20 °C to +60 °C)
Operating Humidity: 0 to 95% (non-condensing)
Operating Altitude: 2000 m
Storage Altitude: 10,000 m
IP Rating: 42 (indoor use only)
Drop Test Requirements: 1 m
EMI, RFI, EMC: FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature Coefficients:

Current:

0.1 % of reading per °C outside 22 °C to 24 °C
Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C
Close Window