The rubberized housing of the MSA Altair Maintenance-Free Single-Gas Detector provides superior dust and water protection!
Features & Applications:
The MSA Altair Maintenance-Free Single-Gas Detector is a high-performance gas monitor that is cost-effective and built to last in tougher environments. Designed with a rubberized housing and patented electrochemical sensors that feature stainless steel construction and contain solid electrolyte, the gas detector offers superior dust and water protection, a high resistance to RFI, and virtually eliminates the possibility of sensor leakage. The gas detector accurately detects oxygen and will last for over two years. One-button operation makes it easy to use, and a triple-alarm system that features two bright LEDs, a piercing audible alarm, and a vibrating alarm ensures that you are always alerted. It automatically records the last 25 alarm and test events.
Features:
- Factory-calibrated detector with
warranted two-year service life
(1080 alarm minutes)
- Maintenance-free; no sensor or battery
changes necessary
- Easy bump check and built-in
calibration feature
- Bump check confirmed with checkmark
on instrument LCD, displayed for 24 hours
- High-capacity battery
- Event recorder stores 25 latest events
automatically in instrument memory
- Built-in gas delivery adapter for gas
response tests (No cal cap to lose)
- Rated to IP67 for dust and water ingress
- Displays sensor life remaining. Displays LO or HI when alarm set-point is exceeded.
Applications:
- Chemical
- Construction
- Electric Utility
- Gas Detection
- General Industry
- Hazardous Materials
- Indoor Air Quality
- Manufacturing
- Nuclear
- Oil and Gas
- Water/Wastewater
Hazards:
- Leak Detection
- Oxygen Deficiency
- Toxic Atmosphere IDLH
- Toxic Atmosphere Non-IDLH
Spec Summary:
| Weight: |
|
| Dimensions: |
| Gases and Measuring Ranges: |
| Gas: |
Range: |
| Oxygen: |
0-25% by vol |
| Alarms: |
Average >95 dB @ 30 cm, Ultra - LED’s, vibrating alarm standard |
| Warranty: |
2 years or 1080 minutes (18 hrs) of alarm under normal conditions |
| Instrument Life: |
2 years at an average of 2 minutes of alarm per day |
| Operating T Range: |
-20ºC to +50ºC |
| Humidity: |
10-95% RH non-condensing |
| Ingress Protection: |
IP67 |
| Event Logging: |
25 Latest Events |
| Certifications: |
US and Canada Class 1, Division 1, Groups A, B, C and D
Europe ATEX II 2G EEx ia IIC T4 -20ºC to +50ºC
Australia Ex ia IIC T4 -20ºC to +50ºC |
|