Alnor Portable Combustion Gas Analyzer w/ RS232 Interface - O2, CO, NO

Alnor Portable Combustion Gas Analyzer w/ RS232 Interface - O2, CO, NO
Item #: 166503
Manufacturer: Alnor Instruments
Manufacturer Item #: CGA-823
Your Price: $1,802.00
This Alnor portable combustion gas analyzer features sensors that are easily recalibrated in the field

Features & Applications:

This portable combustion gas analyzer with O2, CO and NO sensors is a practical tool for boiler maintenance professionals who measure flue gases to tune standard burners or low NOx burners for safe, efficient operation. Real time data including O2, CO, CO2, NO, NOx, combustion temperatures and flue draft pressure are easily viewed on the large LCD display. The calculated efficiency and excess air of a system can be monitored for determining system performance as part of a preventative maintenance program. Print or download current flue gas data or flue gas data saved in the combustion analyzer memory to add to boiler room logs. Factory set fuels with adjustable fuel parameters and an additional user-defined fuel provide fast setup and flexibility for use with fuel from natural gas to wood pellets and bio-diesels.

Features:

  • Replacement sensors need no calibration gas
  • Automatic O2, baseline and auto zeroing of sensors
  • 24-hour battery life
  • Sensors easily recalibrated in the field
  • Sample averages calculated automatically

Includes:

  • Instrument
  • O2 Sensor
  • CO Sensor (H2 Compensated)
  • NO Sensor
  • Model 801989 Gas Sampling Probe (12-inch stainless steel probe, pistol grip handle, 7-foot light-duty sampling hose)
  • Water Trap
  • AC Adapter
  • Four (4) size C alkaline batteries
  • Operation and Service Manual
  • NIST Traceable Certificate of Calibration

Applications:

  • Perform critical safety checks
  • Measure Carbon Monoxide
  • Supplement preventive maintenance
  • Monitor NOx output

Specifications:

Type: Digital Electronic For Oil Heating with Smoke Pump
Fuel Type: One User Defined Plus Natural Gas (Methane), Propane, No 2 Oil, No 6 Oil, Coal, Wood and Coke
Combustion Efficiency: 0 To 99.9%
Oxygen Concentration: 0 To 25%
Carbon Dioxide Concentration: 0 to 25%
Carbon Monoxide Measurement Range (PPM): 0 to 5,000
Primary/Ambient Air Temp: -22 Degree to 140 Degree F
Stack Temp: 0 Degree to 700 Degree C
Pressure/Draft: +/-30" WC
Nitrogen Oxide Concentration: 0 to 4000 PPM
Nitrogen Dioxide Concentration: Calculated
Excess Air: 0 to 1000%
Display: LCD
Battery Type: (4) C
Includes: Batteries, Carrying Case, Sample Probe, Universal AC Adaptor, RS232 Interface and Instructions