Hanna Turbidity Meter Kit w/ Tag Identification System (TIS) Item #: 143430 Manufacturer: Hanna Instruments Incorporated Manufacturer Item #: HI98703 Your Price: $815.95 |
||||||||||||||||||||||||||||||||||||||||||||
This Hanna turbidity meter features a 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failureFeatures & Applications: This Hanna turbidity meter uses a tungsten light source for consistently reliable readings and feature an EPA compliance reading mode. The backlit LCD is easy to read. The light detector used for turbidity readings is a silicon photocell. Free and total chlorine readings are given by a silicon photocell with 525nm narrow band interference filters. Data you have logged can be downloaded through either the RS-232 or USB interfaces. The Tag Identification System (TIS) allows you to record the time and place at unlimited specific measurement locations. Just add iButton® tags near your sampling sites and then use the Meter to identify and authenticate logged data by touching the iButton to the connector on the Meter. Use the Windows® Software to sort or filter all collected data using different criteria-such as specific sampling location, parameter, date and time intervals or fixed range-to filter measured values. Data can be plotted in a graph, exported to other programs or printed. Compliance: USEPA 180.1. To meet EPA reporting requirements these instruments have an EPA compliance reading mode. HI 98703 meets all EPA requirements with regards to the Standard Methods for Turbidity Measurements. Turbidity is measured up to 1000 NTU. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging. Reliable performance of the instrument is validated using Hanna's exclusive Cal Check® system and our ready-made, NiST traceable chlorine standards. For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent Calibration isn't necessary as the system compensates for variations in the intensity of the light source. The instruments' Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instruments is equipped with backlighting. The current date and time can be displayed on the LCD. Includes:
Specifications:
|
|||||||||||||||||||||||||||||||||||||||||||||