Digital Snap-Around Volt-Amp Meter with Free 2008 Doctor Watts Shirt-Pocket Electrical Guide

Digital Snap-Around Volt-Amp Meter with Free 2008 Doctor Watts Shirt-Pocket Electrical Guide
Item #: E719DK
Manufacturer: A.W. Sperry
Manufacturer Item #: DSA-500
Product Type: Clamp Meters
Your Price: $76.95
In Stock

Digital Snap-Around Volt-Amp Meter with 2008 Dr. Watts high quality AC & DC voltage measurement
Features & Applications:

This affordable, lightweight and durable snap-around volt-amp meter will rival more expensive meters, but at a much lower price. AC current, AC & DC voltage, resistance and continuity readings are easily taken.

Despite its low price, useful features are not lacking-it is UL listed, has an electronic overload protector, data hold button, sleep functions and continuity buzzer.

The 2008 Doctor Watts Shirt-Pocket Electrical Guide ($12.95 value) contains a good collection of some of the most useful NEC tables, formulas and calculations.

Features:
  • DC Voltage and AC Voltage Ranges
  • Continuity Buzzer
  • Overload Protection on All Ranges
  • Overvoltage category III 300V, pollution degree 2
  • Overvoltage category II 600V, pollution degree 2
  • Data Hold
  • Includes Industry Standard Safety Probes
  • 2 Recessed Safety Designed Input Terminals
  • Sleep feature to extend battery life
  • Lifetime Limited Warranty


Spec Summary:

Withstand Voltage: 3,700VAC (RMS, 50/60Hz) for 1 minute between electrical circuit and housing case.
Insulation Resistance: 10M Ohm or greater at 1,000V between electrical circuit and housing case.
Dimensions:7"L x 1.75"W x 1.1"D (184 x 44 x 27mm)
Weight: Approx. 7 oz (190g) including batteries

AC Current
Ranges: 40A (0-39.99A)
Ranges: 400A (0-399.9A)
Basic Accuracy: ±2.0%rdg ±6dgt (50/60Hz)

AC Voltage
Ranges: 400V (0-399.9V)
Ranges: 600V (150-599V)
Basic Accuracy: ±2.0%rdg ±5dgt (50/60Hz)

DC Voltage
Ranges: 400V (0-399.9V)
Ranges: 600V (150-599V)
Basic Accuracy: ±1.5%rdg ±5dgt

Resistance
Ranges: 400 Ohm (0-399.9 Ohm)
Ranges: 4,000 Ohm (150-3999 Ohm)
Basic Accuracy: ±2.0%rdg ±5dgt

Note: Free 2008 Doctor Watts Shirt-Pocket Electrical Guide included ($12.95 value).