Get accurate voltage and frequency measurements with the Fluke 87V Industrial True RMS Multimeter
Features & Applications:
Accuracy and diagnostic functions for maximum industrial productivity. The 80 Series 5 model has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems in electronics, plant automation, power distribution, and electro-mechanical equipment.
Features:
- Large display digits and 2 level bright white backlight for increased visibility
- Withstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits and complies with second edition ANSI and IEC electrical safety standards
- Improved sleep mode for long battery life
- Relative mode to remove test lead resistance from low ohms measurements
- Auto and manual ranging for maximum flexibility
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- True-rms ac voltage and current for accurate measurements on non linear signals
- Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Measure up to 1000 V ac and dc
- Measure up to 10 A (20 A for 30 seconds)
- 10,000 uF capacitance range
- Frequency to 200 kHz and % duty cycle
- Peak capture to record transients as fast as 250 μs
- 4½ digit mode
Applications:
- Motor Drives
- In Plant Automation
- Power Distribution
- Electro-mechanical equipment
Spec Summary:
| Specifications: |
Voltage DC: |
Maximum Voltage:1000V
Accuracy: ±(0.05%+1)
Maximum Resolution:
10 µV
|
Voltage AC: |
Maximum: 1000V
Accuracy: ±(0.7%+2) True RMS
AC Bandwidth: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV |
Current DC: |
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: ±(0.2%+2)
Maximum resolution: 0.01 µA |
Current AC: |
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA |
Resistance: |
Maximum Resistance: 50 MOhms
Accuracy: ±(0.2%+1)
Maximum Resolution: 0.1Ohms |
Capacitance: |
Maximum Capacitance: 9,999 µF
Accuracy: ±(1%+2)
Maximum Resolution: 0.01 nF |
Frequency: |
Maximum Frequency: 200 Khz
Accuracy: ±(0.005%+1)
Maximum Resolution: 0.01 Hz
|
Duty Cycle: |
Maximum Duty Cycle: 99.9%
Accuracy: ±(0.2% per khz +0.1%)
Maximum Resolution: 0.1% |
Temperature Measurement: |
-328.0°F - 1994.0°F
-200.0°C - 1090°C
excluding probe |
80 BK Temperature Probe: |
40.0°F - 500°F
-40.0°C - 260°C, 2.2°C or 2% whichever is greater |
Conductance: |
Maximum Conductance: 60.00 nS
Accuracy: ±(1.0%+10)
Maximum Resolution: 0.01 nS |
Diode: |
Range 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1) |
Duty Cycle Range: |
Accuracy: Within ± (0.2% per kHz + 0.1 %) |
| Environmental Specifications: |
Operating Temperature: |
-4 to 131°F (-20 to +55°C) |
Storage Temperature: |
-40 to 140°F (-40 to +60°C) |
Humidity (without Condensation): |
0 to 90% (32 to 95°F)
0 to 70% (95 to 131°F) |
Operating Altitude: |
6,561 ft (2000 m) |
| Safety Specifications: |
Overvoltage Category: |
EN 61010-1 to 1000 V CAT III, 600V CAT IV |
Agency Approvals: |
UL, CSA, TÜV, VDE listed |
| Mechanical & General Specifications: |
Size: |
7.91" x 3.85" x 2.04" (201 x 98 x 52 mm)
with holster |
Weight: |
12.52 oz. (355 g) |
Weight With Holster and Flex-Stand: |
1.37 lb. (624 g) |
Display: |
Digital: 6000 counts updates 4/sec.
(Model 87 also has 19,999 counts in high-resolution mode)
Analog: 32 segments, updates 40/sec.
Frequency: 19,999 counts, updates 3/sec. at >10 Hz |
Warranty: |
Lifetime |
Battery Life: |
Alkaline: ~400 hours typical, without backlight |
Shock: |
3.28 ft. (1 Meter) drop per IEC 61010-1:2001 |
Vibration: |
Per MIL-PRF-28800 for a Class 2 instrument |
|