Professional Equipment     Print Page
PO Box 5197
Janesville, WI 53547-5197

Phone Number: 608-743-8002
Fax Number: 608-743-8039
Toll Free Number: 1-800-334-9291
Toll Free Fax Number: 1-888-776-3187


Amprobe 5XP-A Digital Multimeter with Voltage Detection

Amprobe 5XP-A Digital Multimeter with Voltage Detection
Item #: E601-0567
Manufacturer: Amprobe
Manufacturer Item #: 5XP-A
Product Type: Digital Multimeters
Your Price: $37.95
In Stock

Amprobe 5XP-A Digital Multimeter with Voltage Detection for residential and commercial electrical use
Features & Applications:

The Amprobe 5XP-A Digital Multimeter combines features and accuracy in a small device. Each 5XP-A Multimeter has built-in non-contact voltage (NCV) detection, Magne-Grip holster and CAT III safety ratings.

Features:

  • 27 ranges/10 functions – a complete performance, general purpose digital multimeter
  • VolTect™ Non-Contact Voltage Detector lets you instantly identify dangerous AC voltage
  • Magne-Grip™ holster with magnetic strap frees both hands for work
  • 2000-count 3-1/2 digit display
  • 750 V ac/ 1000 V dc – highest voltage rating in this class of meter
  • Resistance and continuity for troubleshooting bad connections
  • Battery load test with 1.5 volt and 9 volt capabilities
  • Min/Max records minimum and maximum values
  • Data Hold freezes display to “hold” measurement reading

Spec Summary:

Specifications
DC Current:
Ranges 200 µA, 2 mA, 20 mA, 200 mA
Resolution 0.1 µA
Accuracy ± (1.5 % rdg + 1 dgt)
Input protection 315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
Burden voltage 300 mV max. (1 V max. on 200 mA range)
AC Current (45 Hz - 500 Hz):
Ranges 200 µA, 2 mA, 20 mA, 200 mA
Resolution 0.1 µA
Accuracy ± (2.0 % rdg + 5 dgts)
Input protection 315 mA/1000 V fast blow ceramic fuse 6.3 x 32 mm on mA input
Burden voltage 300 mV max. (1 V max. on 200 mA range)
Resistance:
Ranges 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
Resolution 100 mΩ
Accuracy on 200 Ω to 200 kΩ ranges ± (1.0 % rdg + 4 dgts)
Accuracy on 2 MΩ ranges ± (1.5 % rdg + 4 dgts)
Accuracy on 20 MΩ range ± (2.0 % rdg + 5 dgts)
Open circuit volts 0.3 Vdc typical, (3.0 Vdc on 200 Ω range)
Overload protection 1000 VDC or 750 VAC rms
Continuity:
Audible indication 75 Ω ± 25 Ω
Response time 100 ms
Overload protection 1000 VDC or 750 VAC rms
Diode Test:
Test current 1.0 mA (approximate)
Accuracy ± (1.5 % rdg + 3 dgts)
Resolution 1 mV
Open circuit volts 3.0 Vdc typical
Overload protection 1000 VDC or 750 VAC rms
Battery Test:
Ranges 1.5 V, 9 V
Resolution 1 mV, 10 mV
Accuracy ± (3.5 % rdg + 2 dgts)
Loaded current 150 mA typical for 1.5 V range, 5 mA typical for 9 V range
Overload protection 1000 VDC or 750 VAC rms on 9 V range, on VΩ input315 mA/1000 V fast blow ceramic fuse on 1.5 V range, on mA input
Non-Contact Voltage Indicator Sense voltage 70 V to 600 VAC beeper chirps and big bright red LED comes on, works on all ranges

General Specifications
Display:
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
Polarity:
Automatic, positive implied, negative polarity indication
Overrange:
(OL) or (-OL) is displayed
Zero:
Automatic
Low battery indication:
The battery icon is displayed when the battery voltage drops below theoperating level
Measurement rate:
2.5 times per second, nominal
Operating environment:
0 °C to 50 °C at <70 % R.H.
Storage temperature:
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Accuracy:
Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
Temperature coefficient:
0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
Altitude:
6561.7 feet (2000 M)
Power:
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life:
200 hours typical with carbon-zinc
Dimensions:
155 mm (H) x 72 mm (W) x 32 mm (D)
Weight:
Approx. 210 g including battery
Safety:
Designed to meet IEC 1010-1, Rev-2 CAT I 1000 V, CAT II 600 V,CAT III 300 V, class 2 and pollution deg. 2 indoor use. Complies with CE,and CSA 22.2 No. 1010-1 requirements.
Auxiliary Features:
Min/Max Records the maximum reading in a measurement, records the minimum reading in a measurementData hold Freeze the latest reading on the displaymA jack Input warning detects wrong connection

Close Window