Meterman Dual Input Digital Thermometer is a two input digital thermometer with triple display
Features & Applications:
This multiple type input thermometer is designed for HVAC/R technicians, electricians, research, industrial processes, and quality control. The TMD90 accepts type K, J, T, R, S, and E thermocouples. The thermometer ships with deluxe plastic carrying case and two Type K thermocouple probes.
Features:
- High accuracy, multiple type input thermometer
- Measures to 3200°F /1760°C
- Accepts Type J, K, T, R, S, E inputs
- Triple display of T1, T2, T1 - T2, and relative timestamp
- Relative Time stamp to monitor when events occur
- Deluxe hard carry case
- RS232 output with optional cable and software, TM-SW (# T601-0575)
- Min/Max indicators
- One-year warranty
Spec Summary:
| Specifications |
Measurement Ranges: |
| Type K |
-328 to 2498°F (200 to 1370°C) |
| Type J |
-328 to 1400°F (200 to 760°C) |
| Type T |
-328 to 730°F (200 to 390°C) |
| Type R and S |
32 to 3200°F (0 to 1760°C) |
| Type E |
-328 to 1832°F (200 to 736°C) |
|
Type K: |
| Range |
-200 to 650°C |
|
651 to 1370°C |
|
-328 to 1000°F |
|
1001 to 2498°F |
| Resolution |
0.1°C |
|
1.0°C |
|
0.1°F |
|
1.0°F |
| Accuracy |
(0.1 % rdg + 0.7°C) |
|
(0.1 % rdg + 0.7°C) |
|
(0.1 % rdg + 1.4°F) |
|
(0.1 % rdg + 1.4°F) |
|
Type J: |
| Range |
-200 to 500°C |
|
501 to 760°C |
|
-328 to 940°F |
|
941 to 1400°F |
| Resolution |
0.1°C |
|
1.0°C |
|
0.1°C |
|
1.0°F |
| Accuracy |
(0.1 % rdg + 0.7°C) |
|
(0.1 % rdg + 0.7°C) |
|
(0.1 % rdg + 1.4°F) |
|
(0.1 % rdg + 1.4°F) |
|
Type T: |
| Range |
-200 to 390°C |
|
-328 to 730°F |
| Resolution |
0.1°C |
|
0.1°F |
| Accuracy |
(0.1 % rdg + 0.7°C) |
|
(0.1 % rdg + 1.4°F) |
|
Type R/S: |
| Range |
0 to 1000°C |
|
1001 to 1760°C |
|
32 to 1000°F |
|
1001 to 3200°F |
| Resolution |
0.1°C |
|
1.0°C |
|
0.1°F |
|
1.0°F |
| Accuracy |
(0.3 % rdg + 0.7°C) |
|
(0.3 % rdg + 0.7°C) |
|
(0.1 % rdg + 1.4°F) |
|
(0.1 % rdg + 1.4°F) |
|
Type E: |
| Range |
-200 to 380°C |
|
381 to 736°C |
|
-328 to 720°F |
|
721 to 1832°F |
| Resolution |
0.1°C |
|
1.0°C |
|
0.1°F |
|
1.0°F |
| Accuracy |
(0.3 % rdg + 0.7°C) |
|
(0.3 % rdg + 0.7°C) |
|
(0.1 % rdg + 1.4°F) |
|
(0.1 % rdg + 1.4°F) |
|
| General Specifications |
Operating Conditions: |
|
32 to 122°F (0 to 50°C) at 0 to 85% R.H.(non-condensing) |
|
Ambient Coefficient: |
|
0 to 18°C and 28 to 50°C (ambient temperatures) for each °C ambient below 18°C or above 28°C, add the following tolerance into the accuracy spec: 0.01% of reading +0.03°C (0.01 % of reading +0.06°F) |
|
|