| Specifications |
|
DC Voltage: |
Ranges: 340 mV, 3.4, 34, 340 V, 600 V
Accuracy: ± (0.5 % rdg + 2 dgt)
Resolution: 0.1 mV in 3.4 V range
Input Impedance 340 mV range: >100 MΩ
Input Impedance Other ranges: 10 MΩ |
AC Voltage (50-500 Hz): |
Ranges: 3.4 V, 34, 340, 600 V
Accuracy: ± (1.5 % rdg + 8 dgt)
Resolution: 0.1 mV in 3.4 V range
Input Impedance: 10 MΩ |
Resistance: |
Ranges: 340 Ω , 3.4, 34, 340 kΩ , 3.4, 34 MΩ
Accuracy 340 Ω - 340 kΩ: ± (1.0 % rdg + 4 dgt)
Accuracy 3.4 MΩ: ± (1.5 % rdg + 4 dgt)
Accuracy 34 MΩ: ± (3.0 % rdg + 5 dgt)
Max. Open Circuit Voltage 340Ω range: 1.2 V
Max. Open Circuit Voltage All others: 0.45 V |
Diode Test: |
Range: 3.4 V
Accuracy: ± (2.0 % rdg + 3 dgt)
Short Circuit Current: 1.0 mA
Max Open Circuit Voltage: 3.0 VDC
Audible Indication: < 0.2 V |
Continuity Test: |
Display Response: <0.5 s
Continuity Threshold: ≤ 35 Ω |
Overload Protection: |
DC and AC Voltage: 600 VDC or AC rms
Resistance\Continuity\Diode All ranges: 600VDC or VAC rms |
| General Specifications |
|
Display: |
3-3⁄4-digit LCD, 3400 count |
Measuring Rate: |
2.5/ second nominal |
Bargraph: |
34 segments –updated 20 readings per second |
Operating Temperature Range: |
32 to 104°F (0 to 40°C), 80% RH |
Storage Temperature Range: |
68 to 140°F (20 to 60°C), 70% RH |
Environmental: |
Intended for indoor use, altitude up to 6 561" (2000 m) |
Measurement Accuracy: |
x0.1F°/C° |
Batteries: |
2x LR44, SR44 or S76; Life: 100 hours nominal |
Auto Power Off: |
After 10 minutes |
Dimensions: |
7.8˝ x 1.1˝ x 1.4˝ |
Weight: |
4 oz |
Style: |
Digital withauto range |
Volts ac/dc: |
600 V |
Current: |
N/A |
Resistance: |
34 MΩ |
Battery Test: |
N/A |
Continuity Beeper: |
Yes |
Special Features: |
Analog bar graph,Auto Power Off,Data Hold |
Safety Ratings: |
CULUS, CAT III 300 VCAT II 600 V |
Warranty: |
One-year |