The Fluke-707Ex Intrinsically Safe Loop Calibrator is an intrinsically safe loop calibrator that is made for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Eex ia IIC T4) in Zones 1 and 2. This calibrator has a number of useful features and a large display. It is also easy to use with one hand.
Specifications |
|
Current Measurement: |
Range: 0 to 24 mA
Resolution: 0.001 mA
Accuracy: 0.015% Rdg + 2 LSD |
Current Sourcing: |
Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.015% Rdg + 2 LSD
Drive Capability: 700 Ù at 20 mA
|
Current Simulation: |
Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.015% Rdg + 2 LSD |
Loop Power: |
While measuring mA, 24 V |
Voltage measurement: |
Range: 0 to 28 V DC
Resolution: 1 mV
Accuracy: 0.015% Rdg + 2 LSD |
Environmental Specifications |
|
Operating Temperature: |
14 to 131°F (-10 to 55°C) |
Storage Temperature: |
-40 to 140°F (-40 to 60°C) |
Humidity (Without Condensation): |
0 to 95% 32 to 86°F (0 to 30°C)
0 to 75% 86 to 104°F (30 to 40°C)
0 to 45% 104 to 122°F (40 to 50°C) |
Temperature Coefficient: |
-10 to 18°C, 28 to 55°C, ±.005% of range per °C |
Safety Specifications |
|
Safety: |
CSA C22.2 No. 1010.1:1992 |
EMC: |
EN50082-1:1992 and EN55022:1994 Class B |
Maximum voltage: |
30 V (protection circuit for 230 V) |
ATEX certification: |
Ex II G Eex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X |
CE certification: |
EN61010-1 and EN61326 |
Mechanical & General Specifications |
|
Size: |
5.98" x 2.75" x 1.61" (152 x 70 x 41 mm) |
Weight: |
7.9 oz (12.3 oz including holster)
[224 g (350 g including holster)] |
Batteries: |
One 9V battery Alkaline |
Warranty: |
One year |
Shock & Vibration: |
Per MIL-T-28800 for a Class 2 Instrument |