A compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting, the Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.
Specifications |
|
Maximum voltage between
any terminal and earth ground: |
600 V |
Surge protection: |
6 kV peak per IEC 61010-1 600 VCAT III,
Pollution Degree 2 |
Display: |
Digital: 6,000 counts, updates 4 per second |
Bar graph: |
33 segments, updates 32 per second |
Operating Temperature: |
14 to 122°F (-10 to + 50°C) |
Storage Temperature: |
-40 to 140°F (-40 to + 60°C) |
Battery type: |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life: |
400 hours typical, without backlight |
Accuracy Specifications |
|
DC millivolts: |
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 2.0% + 3 |
DC volts: |
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V |
Auto volts: |
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms: |
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms: |
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity: |
Range: 600 ohms
Resolution: 1 ohms
Accuracy: Beeper on < 20 ohms, off > 250 ohms;
detects opens or shorts of 500 µs or longer. |
Ohms: |
Range/Resolution: 600.0 ohms / 0.1 ohms
Range/Resolution: 6.000 kohms / 0.001 kohms
Range/Resolution: 60.00 kohms / 0.01 kohms
Range/Resolution: 600.0 kohms / 0.1 kohms
Range/Resolution: 6.000 Mohms / 0.001 Mohms
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 Mohms / 0.01 Moms
Accuracy: 1.5 % + 2 |
Diode Test: |
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2 |
Capacitance: |
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 ¥ìF
Accuracy: 5% + 20% |
LoZ capacitance: |
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical |
Temperature2 (Type-K thermocouple): |
Range/Resolution: -40 to 400 °C / 0.1 °C
Accuracy: 1% + 102
Range/Resolution: -40°F to 752 °C / 0.2 °F
Accuracy: 1% + 182 |
AC µamps true-rms (45 Hz to 500 Hz): |
Range/Resolution: 600.0 µA / 0.1 µA
Accuracy: 1.0% + 2 |
DC µamps: |
Range/Resolution: 600.0 µA / 0.1 µA
Accuracy: 1.0% + 2 |
Hz (V or A input)2: |
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2 |