Measure a variety of gases with this compact, waterproof, and dust-resistant gas monitor!
Features & Applications:
The Dräger X-am 2000 is the new generation of gas measurement instruments. Designed with the new minimized, high-performance Dräger XXS-sensors, the instrument delivers readings quickly and can perform a bump test in only 10 seconds. Ideal for personal air monitoring, the Dräger X-am 2000 features an integrated rubber boot, and for additional protection: gas access from two sides to prevent the sensors from being covered, and dust and water density rated to IP 67.
Features:
- Large display
- Crocodile clip
- Ergonomic instrument the size of a mobile phone
- Vapour-sensitive Ex measurement
- Electrochemical sensors offer an
expected lifetime up to five years
- Water and
dust-resistant to IP 67
- Integrated rubber protection and shockproof
sensors
- Able to withstand
electromagnetic interference
- Audio, visual, and vibration alarms
- Equipped as standard with a
data logger
Spec Summary:
| Dimensions (W x H x D) |
1.85 x 5.08 x 1.22 |
|
| Weight |
7.8 oz. |
|
| Ambient conditions |
Temperature: |
-4 to 122°F |
| |
Pressure: |
20.7 to 38.4 inch Hg |
| |
Humidity: |
10 to 95 % r. F |
| Sensor |
Measurement range |
Response time T50 [sec.] |
Expected lifetime
[years] |
| Ex |
0-100 % LEL or 0-5 vol.-% |
8 |
4 |
| IP protection class |
Instrument and sensor block, IP 65 |
|
| Alarms |
Visual |
180° |
| Audible |
Multi-tone >90 dB at 1 ft. |
| Vibration |
| Operating times |
Alkaline |
> 12 hours |
| |
T4 battery pack |
> 12 hours |
| Charging times |
< 4 hours |
| Data logger |
Can be read out via IR > 1000 hours with 4 sensors and a recording interval of
1 reading per minute |
| Approvals* |
ATEX |
II 2G EEx ia d IIC T4/T3
I M2 EEx ia d I |
| |
UL |
Class I Div. 1 Group A, B, C, D T.-Code T4/T3 |
| |
CSA |
Class I Div. 1 Group A, B, C, D T.-Code T4/T3 |
| |
IECEx |
Ex ia d I/IIC T4/T3 |
| |
CE-mark |
Electromagnetic compatibility (directive 89/336/EEC) |
* pending
|