Rely on the Drager X-am 2000 EX for fast warnings of harmful levels of O2, CO, and H2S
Features & Applications:
The Dräger X-am 2000 is the new generation of gas measurement instruments, which is adjusted to the requirements for personal monitoring. With an integrated rubber boot, gas access from two sides, which prevents the sensors from being covered, and dust and water density according to IP 67 the Dräger X-am 2000 offers much more reliability.
The new minimized, high-performance Dräger XXS-sensors have fast response times and give the possibility of performing a bump test in only 10 seconds. Furthermore, they offer a lifetime of 5 years. With its convenient mobile phone shape, low weight and long-life sensors for a favorable price, the Dräger X-am 2000 is the perfect companion for personal air monitoring.
Features:
- Large display
- Crocodile clip
- Ergonomic instrument the size of a mobile phone
- Vapor-sensitive Ex measurement
- Electrochemical sensors offer an
expected lifetime up to five years
- Water and
dust-resistant to IP 67
- Integrated rubber protection and shockproof
sensors
- Able to withstand
electromagnetic interference
- Audio, visual, and vibration alarms
- Equipped as standard with a
data logger
Spec Summary:
| Dimensions (W x H x D) |
1.85 x 5.08 x 1.22 |
|
| Weight |
7.8 oz. |
|
| Ambient conditions |
Temperature: |
-4 to 122°F |
| |
Pressure: |
20.7 to 38.4 inch Hg |
| |
Humidity: |
10 to 95 % r. F |
| Sensor |
Measurement range |
Response time T50 [sec.] |
Expected lifetime
[years] |
| Ex |
0-100 % LEL or 0-5 vol.-% |
8 |
4 |
| O2 |
0-25 vol.-% |
6 |
5 |
| CO |
0-2000 ppm |
6 |
5 |
| H2S |
0-200 ppm |
6 |
5 |
| IP protection class |
Instrument and sensor block, IP 65 |
|
| Alarms |
Visual |
180° |
| Audible |
Multi-tone >90 dB at 1 ft. |
| Vibration |
| Operating times |
T4 battery pack |
> 12 hours |
| Charging times |
< 4 hours |
| Data logger |
Can be read out via IR > 1000 hours with 4 sensors and a recording interval of
1 reading per minute |
| Approvals* |
ATEX |
II 2G EEx ia d IIC T4/T3
I M2 EEx ia d I |
| |
UL |
Class I Div. 1 Group A, B, C, D T.-Code T4/T3 |
| |
CSA |
Class I Div. 1 Group A, B, C, D T.-Code T4/T3 |
| |
IECEx |
Ex ia d I/IIC T4/T3 |
| |
CE-mark |
Electromagnetic compatibility (directive 89/336/EEC) |
* pending
|