Draeger's Pac III Gas Monitor Kit includes software, a download module, cable, and 110 V adapter!
Features & Applications:
The Drager Pac III Hygiene Datalogger is able to record and store in excess of 125 hours @ 1 minute intervals of gas exposure. The averaging period is adjustable to extend the recording length, or shorten the averaging period for better resolution of quickly changing conditions. The kit includes GasVision Software, a download module, cable, and a 110 V power adapter.
The Hygiene version of the Pac III is available for any application that requires documentation and calculation of exposures against the TWA, STEL, or Ceiling values.
The included Software Kit for this Hygiene Monitor consists of GasVision Software, download module, cable, and 110 V power adapter.
Features:
- Intelligent sensor technology
- Dust tight, water resistant, metal plated case
- Two user settable alarm points
- Large backlit LCD screen
- Three buttons control all of the monitor’s functions
- Sensors must be purchased separately and may be quickly switched in the field
- Uses an alkaline battery that yields over 600 hours of operation
- Compliance: UL Class I and II, Division 1, Groups A-G (T6). CSA Class I, Division 1, Groups A-D (T4). CENELEC EEx ia IIC T4/T6 (BVS). MSHA: Permissible Gas Monitor. IP-66 enclosure rating
- 9-V alkaline battery
- Allen tool
- Belt clip
- GasVision Software
- Download module
- Cable
- 110 V power adapter
- Leather carry case
Spec Summary:
Dimensions: |
2.6 x 4.3 x 1.3" (67 x 116 x 32 mm) |
Weight: |
7.0 oz. (200g) |
Environmental Conditions: |
Continuous; -4 to 122°F (-20 to 50°C)
Intermittent; -40 to 132°F (-40 to 55°C) |
Typical Battery Life (@ 77°F/25°C): |
Alkaline; 600 hours
NiMH; 200 hours |
Audible Alarm: |
Peizo-electric buzzer, 95 dBA @ 1ft. |
Visual Alarm: |
Two high intensity LED’s |
Warning Signals: |
A1, A2, TWA, STEL, and low battery
(exposure alarms per ACGIH or TRGS 402) |
Enclosure Rating: |
Ingress Protection, IP-66 |
Datalogger Capacity (Hygiene version): |
>125 hours (with one-minute averages) |
Approvals: |
UL Class I & II, Division 1, Groups A-G (T6)
CSA Class I, Division 1, Groups A-D (T4)
MSHA: Permissible Gas Monitor
ATEX II I G EEx Ia II C T4
Demko O2 ATEX 0135331 |
Note: No sensors included
|