Fluke 1744 Power Quality Logger-Memobox

Fluke 1744 Power Quality Logger-Memobox
Item #: 148355
Manufacturer: Fluke Electronics
Manufacturer Item #: 2583422 FLUKE 1744
Your Price: $5,307.95
The reliable Fluke 1744 Power Quality Logger is easy to set up and measures voltage with premium accuracy!
Features & Applications:

The Fluke 1744 Power Quality Logger is an everyday power meter for technicians who troubleshoot and analyze power quality issues. Capable of simultaneously logging up to 500 power parameters for up to 85 days and monitoring for events, this power logger helps uncover intermittent and hard-to-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.

Features:

  • Measures voltage and current harmonics, interharmonics, mains signaling, unbalance, and frequency
  • Plug and play: Setup in minutes with automatic current probe detection and powering
  • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power
  • Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
  • Monitors power for the long-term: Data can be downloaded during recording without interruption
  • Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1%)
  • Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
  • Rugged and reliable: Designed for everyday field use with no moving parts and durable insulated case with two year warranty

Applications:

  • Disturbance analysis – Uncover root cause of equipment malfunction for later mitigation and predictive maintenance
  • Quality of service compliance – Validate incoming power quality at the service entrance
  • Power quality studies – Assess baseline power quality to validate compatibility with critical systems before installation
  • Load studies – Verify electrical system capacity before adding loads
  • Energy and power quality assessment – Validate performance of facility improvements by quantifying energy consumption, power factor, and general power quality before and after improvements

Spec Summary:

General Data
Intrinsic error
Refers to the reference conditions and is guaranteed for two years
Warranty
2 years
Recalibration interval
2 years recommended
Quality system
developed, designed, and manufactured according to DIN ISO 9001
Reference conditions
23 °C ± 2 K; 74 °F ± 2 K , Vm=230 V ± 10%, 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Phase sequence: L1, L2, L3
Interval length: 10 minutes
Wye connection: (L1, L2, L3 to N)
Power supply: 88 V ... 265 V AC
Environment conditions
Working temp. range: -10 °C to 55°C; 14 °F to 131°F
Operating temp. range: 0 °C to 35°C; 32 °F to 95°F
Storage temp. range: -20 °C to 60°C; -4 °F to 140°F
Reference temp. range: 23 °C ± 2 K; 74 °F ± 2 K
Relative humidity: Fluke 1745: Class B2 acc. IEC 60654-1
Fluke 1744/43: Class C2 acc. IEC 60654-1
Housing
robust, fully insulated housing and accessories
Protection type
Fluke 1745: IP50 as per EN 60529
Fluke 1744/1743: IP65 as per EN 60529
Safety
IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation
Type test voltage
5.2 kV rms, 50 Hz / 60 Hz, 5 s
EMC
Emission: IEC/EN 61326-1, EN55022
Immunity: IEC/EN 61326-1

Voltage and Current Measurement
Input voltage
Input range VI P-N: max 480 V AC
Input range VI P-P: max 830 V AC
Max. overload voltage: 1.2 VI
Input range selection: By job programming
Connections: P-P or P-N, 1- or 3-phase
Nominal voltage VN: <= 999 kV with PTs and ratio
Input resistance: App. 820 kΩ per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kΩ
Intrinsic uncenrtainty: 0.1 % of VI
Voltage transformer: Ratio: <999 kV / VI
Ration selection: By job programming
Current input with Flexi Set
Input ranges II L1 or A, L2 or B, L3 or C, N: 15 A / 150 A / 1500 A / 3000 A ac
Measuring range: 0.75 A … 3000 A ac
Intrinsic uncertainty: < 2 % of II
Position influence: Max. ± 2 % of measured value – for distance conductor to meas. head > 30 mm
Stray field influence: < ± 2 A ac for Iext=500 A ac and distance to measuring head > 200 mm
Temperature coefficient: < 0.05 % / K
Current transformer: Ratio <= 999 kA / II
Ratio selection: By job programming
Connection: 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector
Current input for clamp
Input ranges II L1 or A,
L2 or B, L3 or C, N:
0.5 V nominal (for II) 1.4 Vpeak
Intrinsic uncertainty: < 0.3 % of II
Max. overload: 10 V ac
Input resistance: App. 8.2 kΩ
Current transformer: Ratio Ω 999 kA / II
Power systems
Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase

Logger
Power supply
Functional Range: 88 V to 660 V absolute, 50 Hz / 60 Hz
100 V to 350 V dc Internal fuse: 630 mA T
Power consumption: 5 Watts
Ride through: Fluke 1745: Internal battery for typ. > 5 hours ride through with intelligent power management
Fluke 1743/44: 3 sec Capacitor
Fuse: Power supply fuse can be replaced in service facility only. Supply can be connected in parallel to measuring inputs (up to 660 V)
Display, indicators
LEDs for status and voltage levels
Fluke 1745: LC-display with backlight for voltage, current, active power, phase sequence.
Memory
Capacity 8 MB Flash-EPROM
Intervals: A function > 12000 intervals for > 85 days with 10 min intervals
P function > 30000 intervals for > 212 days with 10 min intervals
Events: > 13000
Memory model: linear, circular
Interface
RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication
Dimensions
Fluke 1745: 282 mm x 216 mm x 74 mm (115in x 88in x 33in)
Fluke 1743/1744: 170 mm x 125 mm x 55 mm (69in x 51in x 22in)
Weight
Fluke 1745: approx. 3 kg
Fluke 1744/1743: approx. 2 kg
Measurement
A/D converter: 16 bit, sample rate: 10.24 kHz
Anti-aliasing filter: FIR-Filter, fc =4.9 kHz
Frequency response: Uncertainty < 1 % of Vm for 40 Hz to 2500 Hz
Interval length: 1, 3, 5, 10, 30 s, 1, 5, 10, 15, 60 minutes
Averaging time for Min/max values: ½, 1 mains period, 200 ms,1 , 3 , 5 s
Time base: Resolution: 10 ms (at 50 Hz), deviation: 2s/day at 23 °C; 74 °F ± 2 K