Bacharach Informant 2 Gas Leak Detector pinpoints detection of both refrigerant and combustible gas leaks
Features & Applications:
Its unique combination of state-of-the-art patented sensor technology, advanced software design and microprocessor controlled circuitry offers you unmatched precision coupled with tremendous speed. It is unquestionably the most sensitive, most reliable, most accurate leak detector on the market today. And the fastest.
Swap sensor tips within seconds and never worry about adjusting sensitivity levels–it's taken care of automatically–even where high levels of background vapors or refrigerants are present. The refrigerant sensor tip is finely tapered to 0.2 inch diameter–so you can get in between coils and fittings, gaining access to hard to reach areas.
The Bacharach Informant2 leak detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of refrigerant or combustible gases.
Features:
- One instrument-two functions
- Lightweight and ergonomically designed
- Swap sensor tips in seconds
- Microprocessor controlled for accuracy and reliability
- Sensitivity is automatically adjusted
- Sensors are the industry's most responsive
- Hydrophobic filter prevents moisture contamination
- Rubber boot holds MagLite® flashlight
- Sequential flashing probe tip, dual LED displays and loud tick rate indicates relative concentration levels
- Detects all halogens and scores of hydrocarbon gases
- Response time is two-tenths of one second
Probe length adjustable from 3 to 20"
Applications:
- Air conditioning units
- Refrigeration systems
- Residential, commercial and industrial
appliances/equipment
- Gas lines
- Gas valves
- Regulators and meters on
gas equipment
Spec Summary:
|
Sensing Elements: |
Refrigerant - Heated Diode, U.S. Patent No. 5,932,176
Combustible - Patented semiconductor type, 5 year typical life, plug-in replacement |
|
Refrigerants Detected: |
All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A, R-408A,
R-409A
and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or Bromine gas) |
|
Combustible Gases Detected: |
All combustible gases and vapors |
|
Alarm Sensitivity: |
Refrigerant 0.25 oz/year of R134a (hardest to detect refrigerant)
Combustibles Minimum 50 PPM (Methane) |
|
Alarm Types: |
Audible and dual visual LEDs |
|
Power Source: |
Four (4) AA disposable alkaline batteries included |
|
Warm-up Time: |
10 seconds |
|
Response Time: |
0.2 second |
|
Battery Life: |
4 to 5 hours, under typical intermittent operation. |
|
Probe: |
20" (50.8cm) maximum length, fully extended; 3" (7.62cm) if wrapped around instrument. Includes LED indicator |
|
Size: |
1.75 W (4.44cm) x 9.62 L (24.43cm) x 2.25"H (5.72cm) |
|
Weight: |
0.86 lbs. (0.39kg) with batteries |
|
Agency Approvals: |
Refrigerant UL listed in accordance with SAE J1627
Combustible MET Lab certified to UL 913, intrinsically safe for use in Class I, Division 1, Group D hazardous areas. |
|
CE-Mark: |
Independently tested |
|