Use this Amprobe ACD-10 TRMS-PLUS 600A Clamp-On Multimeter to take more accurate measurements!
Features & Applications:
To take more accurate measurements in noisy locations this True RMS is the perfect solution. With its slender jaws, this Clamp-On Multimeter has the ability to take measurements in even the most constricted locations. It is a very resourceful tool to have on hand for the fact that it is also capable to measure capacitance and frequency. When measuring frequency it can be done with either the multimeters jaw or test leads.
Features:
- TRMS Measurement
- AC & DC voltage to 600V
- AC current to 600A
- Thin jaws to get in tighter spots
- Continuity buzzer
- Capacitance to 3000 uF
- Frequency measurement
- In rush current
- Can handle conductors up to 26mm (1.02) in diameter
- Hold & Maximum reading functions
- Auto ranging
- Auto power off
- Overload protected
- Rubber over-molded case
Spec Summary:
| Display: |
3-3/4 digits 4000 counts LCD display |
| Update Rate: |
3 per second nominal |
| Polarity: |
Automatic |
| Operating Temperature: |
0°C to 40°C; < 80% RH for temperature up to 31°C decreasing linearly to 50% RH at 40°C |
| Altitude: |
Operating below 2000m; Indoor use |
| Storage Temperature: |
-20°C to 60°C, < 80% RH (with battery removed) |
| Temperature Coefficient: |
Nominal 0.15 x (specified accuracy)/°C @ (0 °C ~ 18 °C or 28 °C ~ 40 °C) |
| Low Battery: |
Below approx. 2.4V |
| Power Supply: |
3V coin battery IEC-CR2032 |
| Power Consumption: |
2.8 mA typical except that 3.3 mA typical for ACA function |
| APO Timing: |
Idle for 30 minutes |
| APO Consumption: |
5 μA typical |
| Dimension: |
7.4 x 2.5 x 1.3 in. (190 x 63 x 32 mm) |
| Weigth: |
Approx 139 gm |
| Jaw Opening and Conductor Diameter: |
Max 26 mm |
| Special Features: |
30ms Max Hold; Data Hold; Relative Zero mode |
| Safety: |
Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. CAT lll-600 Volts ac & dc; Pollution degree : 2 |
| EMC: |
Conforms to EN61326-1 |
Electrial Spec Accuracy (23 °C ± 5 °C & < 75% R.H.):
| Function |
Range |
Accuracy |
| DC Voltage |
400.0 mV |
±( 0.3% + 4 digits) |
| 4.000, 40.00, 400.0V |
±( 0.5% + 3 digits) |
| 600 V |
±( 1.0% + 4 digits) |
| NMRR: |
>50 dB @ 50/60Hz |
| CMRR: |
>120 dB @ DC, 50/60 Hz, Rs=1 kΩ |
| Input Impedance: |
10 MΩ, 30 pF nominal (1000 MΩ for 400.0 mV range) |
| Transient Protection: |
6.5 kV (1.2/50 μs surge) |
| AC Voltage (50Hz ~ 500Hz): |
4.000, 40.00, 400.0V |
±( 1.5% + 5 digits) |
| 600V |
±( 2.0% + 5 digits) |
| CMRR: |
>60dB @ DC to 60 Hz, Rs=1 kΩ |
| Maximum Crest Factor: |
< 1.75 : 1 at full scale & < 3.5 : 1 at half scale limited to
fundamental and harmonics, that fall within the meter
specified AC bandwidth for non-sinusoidal waveforms |
| Imput Impedance: |
10 MΩ, 30 pF nominal |
| Transient Protection: |
6.5 kV (1.2/50μs surge) |
| ACD-10 Plus: |
True RMS sensing - 5% to 100% of range |
| AC Current (Clamp-on 50Hz/60Hz) |
Range: |
Accuracy 1) 2) 3): |
| 40.00, 400.0, 600A |
±( 1.5% + 8 digits) |
| Overload: Protections: |
ACA Clamp-on jaws : 600 A rms continuous |
| ACD-10 Plus: |
True RMS sensing - 10 % to 100 % of range |
1) Max Induced error from adjacent current carrying conductor: 0.05 A
2) Specified accuracy is from 1% to 100% of range and for measurements made at the jaw center. When the conductor is not positioned
at the jaw center, position errors introduced are: Add 2% to specified accuracy for measurements made BEYOND jaw marking
lines (toward jaw opening)
3) Add 8 digits to specified accuracy @ reading < 10% of range |
| Resistance: |
400.0 Ω |
±( 0.8% + 8 digits) |
| 4.000, 40.00, 400.0 kΩ |
±( 0.6% + 4 digits) |
| 4.000 MΩ |
±( 1.0% + 4 digits) |
| 40.00 MΩ |
±( 2.0% + 4 digits) |
| Open Circuit Voltage : |
0.4 VDC typical |
| Transient protection : |
6.5 kV (1.2/50μs surge) |
| Frequency: |
| Function |
Sensitivity (Sine RMS) |
Range |
Accuracy |
| 400.0 mVac |
350mV 1 |
0 Hz ~ 2 kHz |
±( 0.5%+4 digits) |
| 4.000 Vac |
1V |
5 Hz ~ 5 kHz |
±( 0.5%+4 digits) |
| 4.000, 40.00 Vac |
32V |
5 Hz ~ 100 kHz |
±( 0.5%+4 digits) |
| 400.0 Vac |
90V |
5 Hz ~ 10 kHz |
±( 0.5%+4 digits) |
| 600 Vac |
500V |
5 Hz ~ 5 kHz |
±( 0.5%+4 digits) |
| 400.0 Aac |
60A |
40 Hz ~ 400 Hz |
±( 0.5%+4 digits) |
| Display Counts: |
|
5000 |
|
| Resolution: |
|
0.001Hz |
|
| Overload Protection: |
|
ACA Clamp-on jaws : AC 600A rms continuous |
|
| Transient Protection: |
|
VAC input jacks : 6.5kV (1.2/50μs surge) |
|
| Capacitance: |
| |
Range 1): |
Accuracy 2) 3): |
| 500.0μF, 5.000μF, 50.00μF, 500.0μF, 3000μF |
±( 3.5% + 6 digits) |
1) Additional 50.00nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8V (approximately half full battery).
Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V |
| Transient Protection: |
6.5 kV (1.2/50 μs surge) |
| Audible Continuity Tester: |
| Audible Indication: |
between 10 Ω and 120 Ω. |
| Transient Protection: |
6.5 kV (1.2/50 μs surge) |
| Diode Tester / Open Circuit Voltage Test Current: |
| (Typical): |
< 1.6 VDC @ 0.25 mA |
| Transient Protection |
6.5 kV (1.2/50 μs surge) |
Max Hold* (where applicable): Specified accuracy ± 50 digits for changes > 25 ms in duration
|