Convenient hand straps and a belt loop are provided for carrying the instrument. A small pocket is provided for a check source. The unique design of attaching the probe to the carrying case allows one-handed operation if desired. The protective probe cover folds easily out of the way during one-handed operation.
| Detector: |
RAP-RS1 Probe - External Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0 mg/cm2 areal density. Effective diameter of window is 45 mm (1.75 in.). Radiation symbol on front label marks the center of the detector. Anodized aluminum housing with coated, black foam grip. 500-volt power supply is in the probe head.
Size- Approx. length: 22.2 cm (8.75 in.)
Diameter: 7 cm (2.75 in.)
Connector - Amphenol tuchel connectors
|
| Display: |
4 digit liquid crystal display with indicators |
| Averaging Periods: |
Display will update every 3 seconds. At low background levels, the update is the moving average for the past 30-second time period. The timed period for the moving average decreases as the radiation level increases |
| Alert Set Range: |
mR/hr .001 to 50 and CPM 1-160,000 |
| Count Light |
Red LED flashes with each radiation event |
| Audio Indicator: |
Internally mounted beeper (can be switched off for silent operation)
|
Outputs:
|
Dual miniature jack drives CMOS or TTL devices: count to computer or datalogger. Submini jack input allows for electronic calibration
|
| Anti-Saturation: |
Meter will hold at full scale in fields as high as 100 times the maximum reading. |
| Power Requirements: |
One 9-volt alkaline battery. Battery life is 2160 hours at normal background. |
| Gamma Sensitivity: |
3500 CPM/mR/hr referenced to Cs-137. Smallest detectable level for I-125 is .02 µCi at contact. Timer can set 1 minute sampling periods from 1 to 10 minutes. |
| Timer: |
Timer can set 1 minute sampling periods from 1 to 10 minutes. 10 minute sampling periods 10-60 minutes. 1 hour sampling periods from 1-24 hours. |
| Operating Range: |
mR/hr - .001 (1µR) to 100 mR/hr
CPM - 0 to 300,000
µSv/hr - .01 to 1000
CPS - 0 to 5000
Total/ Timer - 1 to 9,999,000 counts |
| Accuracy: |
mR/hr ±15% 0 to 50
mR/hr ±20% 50 to 100
CPM ±15% 0 to 130,000
CPM ±20% 130,000 to 300,000
(Referenced to Cs-137) |
| Temperature Range: |
-10ºC to 50ºC (14ºF to 122ºF) |
| Weight: |
Inspector: 420 grams (1 lb 15.6 oz.) without battery |
| Size: |
150 x 80 x 30 mm (5.9 x 3.3 x 1.2 in) |
| Includes: |
Carrying case, CE Certification for European Sales |
| Warranty: |
90 day Warranty on GM Detector, 1 year limited |